0 like search mail home
選擇產品功能 arrow_down

電化學 / 材料 / 儲能裝置測試

electrochemistry/material/ Energy storage device test
  • 鉑網電極

    鉑網電極

    Platinum (Pt) Mesh Electrode
    MW-4132
    • 鉑網電極
    • 面積2.0cm×2.0cm
    • 線徑0.1mm,
    • 99.9%純度
    加入諮詢
    加入諮詢
  • Thin-film Platinum InterDigitated Ring Array microelectrode (10/10 µm)

    Thin-film Platinum InterDigitated Ring Array microelectrode (10/10 µm)

    Thin-film Platinum InterDigitated Ring Array microelectrode (10/10 µm)
    ED-IDRA1-Pt
    12 pairs interdigitated platinum electrodes (10/10 µm, electrode/gap) with radial design focused on flow analysis systems. Compatible with Drop, AIO and Multi8x AIO cell.
    加入諮詢
    加入諮詢
  • Thin-film Gold InterDigitated Ring Array Microelectrode (10/10 µm)

    Thin-film Gold InterDigitated Ring Array Microelectrode (10/10 µm)

    Thin-film Gold InterDigitated Ring Array Microelectrode (10/10 µm)
    ED-IDRA1-Au
    12 pairs interdigitated gold electrodes (10/10 µm, electrode/gap) with radial design focused on flow analysis systems. Compatible with Drop, AIO and Multi8x AIO cell.
    加入諮詢
    加入諮詢
  • Thin-film Platinum InterDigitated Array Microelectrode (5/5 µm)

    Thin-film Platinum InterDigitated Array Microelectrode (5/5 µm)

    Thin-film Platinum InterDigitated Array Microelectrode (5/5 µm)
    ED-IDA6-Pt
    30 pairs interdigitated platinum electrodes (5/5 µm, electrode/gap) integrating reference and counter electrode. Useful for gas sensor (oxygen, nitrogen dioxide…), explosives, etc... detection. Compatible with Drop, AIO and Multi8x AIO cell.
    加入諮詢
    加入諮詢
  • Thin-film Gold InterDigitated Array Microelectrode (5/5 µm)

    Thin-film Gold InterDigitated Array Microelectrode (5/5 µm)

    Thin-film Gold InterDigitated Array Microelectrode (5/5 µm)
    ED-IDA6-Au
    30 pairs interdigitated gold electrodes (5/5 µm, electrode/gap) integrating reference and auxiliary electrodes. Useful for thiols, uric acid, ascorbic acid, cancer biomarkers, insecticides, etc... detection. Compatible with Drop, AIO and Multi8x AIO cell.
    加入諮詢
    加入諮詢
  • Thin-film Platinum InterDigitated Array Microelectrode (10/5 µm)

    Thin-film Platinum InterDigitated Array Microelectrode (10/5 µm)

    Thin-film Platinum InterDigitated Array Microelectrode (10/5 µm)
    ED-IDA5-Pt
    Thin-film Platinum InterDigitated Array Microelectrode (10/5 µm) 
    20 pairs interdigitated platinum electrodes (10/5 µm, electrode/gap) integrating reference and auxiliary electrodes. Useful for gas sensor (oxygen, nitrogen dioxide…), explosives, etc... detection. Compatible with Drop, AIO and Multi8x AIO cell.
    加入諮詢
    加入諮詢
  • Thin-film Platinum InterDigitated Array Microelectrode (10/10 µm)

    Thin-film Platinum InterDigitated Array Microelectrode (10/10 µm)

    Thin-film Platinum InterDigitated Array Microelectrode (10/10 µm)
    ED-IDA1-Pt
    15 pairs interdigitated platinum electrodes (10/10 µm, electrode/gap) integrating reference and counter electrodes. Useful for gas sensor (oxygen, nitrogen dioxide…), explosives, etc... detection. Compatible with Drop, AIO and Multi8x AIO cell.
    加入諮詢
    加入諮詢
  • Thin-film Gold InterDigitated Array Microelectrode (10/10 µm)

    Thin-film Gold InterDigitated Array Microelectrode (10/10 µm)

    Thin-film Gold InterDigitated Array Microelectrode (10/10 µm)
    ED-IDA1-Au
    15 pairs interdigitated gold electrodes (10/10 µm, electrode/gap) integrating reference and auxiliary electrodes. Useful for thiols, uric acid, ascorbic acid, cancer biomarkers, insecticides, etc... detection. Compatible with Drop, AIO and Multi8x AIO cell.
    加入諮詢
    加入諮詢
  • Thin-film Platinum InterDigitated Electrode (5/5 µm)

    Thin-film Platinum InterDigitated Electrode (5/5 µm)

    Thin-film Platinum InterDigitated Electrode (5/5 µm)
    ED-IDE3-Pt
    180 pairs of interdigitated platinum electrodes (5/5 µm, electrode/gap). Useful for optics, electrochemistry, scanning electrochemistry microscopy, etc. Compatible with Drop, AIO and Multi8x AIO cell.
    加入諮詢
    加入諮詢
  • Thin-film Gold InterDigitated Electrode (5/5 µm)

    Thin-film Gold InterDigitated Electrode (5/5 µm)

    Thin-film Gold InterDigitated Electrode (5/5 µm)
    ED-IDE3-Au
    180 pairs of interdigitated gold electrodes (5/5 µm, electrode/gap). Useful for optical and electrochemical (impedance) studies, spectroelectrochemistry, etc. Compatible with Drop, AIO and Multi8x AIO cell.
    加入諮詢
    加入諮詢