Norecs

Norecs
  • 隔絕管

    隔絕管

    Shielding tube
    The ProboStat™ can be delivered with an stainless steel enclosing tube welded on a socket. The tube either replaces the standard alumina/quartz enclosing tube, or is mounted on the outside of this tube.
    加入諮詢
    加入諮詢
  • 燃料電池測試系統概要

    燃料電池測試系統概要

    ProboStat, overview
    The ProboStat™ is a cell for measurements of electrical properties, transport parameters, and kinetics of materials, solid/gas interfaces and electrodes under controlled atmospheres at elevated temperatures up to 1600ºC. The versatile construction and broad range of accessories of the system are based on years of development and experience in the Kofstad/Norby group at the University of Oslo. A ProboStat™ system offers a cost-effective alternative to developing and building your own cell for studies, characterization and testing of inorganic materials, electroceramics, fuel cell components, membrane materials, etc.
    加入諮詢
    加入諮詢
  • 氧氣感測

    氧氣感測

    Oxygen sensors
    The use of controlled atmospheres during measurements at high temperatures is a specialty of the ProboStat. Nevertheless, the establishment of controlled atmospheres is not entirely trivial. This is mainly done before the gas enters the ProboStat, and may require one or more of prefabricated gas mixtures, gas mixing, total pressure control, electrochemical pumping, wetting, and drying and other filtering/gettering.
    加入諮詢
    加入諮詢
  • 擴充系統

    擴充系統

    Extensive System
    • Disk samples of varying diameters
    • Controlled atmospheres and concentration cells
    • 2, 3 and 4 electrode setups
    • van der Pauw 4-point measurements
    • Bar samples (4-point and Seebeck)
    • Conductivity, impedance spectroscopy, DC measurements
    • Transport number, permeability, etc.
    加入諮詢
    加入諮詢
  • 客製化加熱方案

    客製化加熱方案

    Custom heating solutions
    • gas line heating,
    • membrane heating,
    • uniform or non-uniform heat regions,
    • heat gradients,
    • low voltage heating,
    • heat radiation,
    • heat conductance,
    • heat convection.
    加入諮詢
    加入諮詢
  • 高壓標準系統

    高壓標準系統

    High Voltage Normal System
    • Polarization of dielectrics, breakdown tests, plasma electrodics etc. 
    • Controlled atmospheres or vacuum 
    • Tolerate to > 10 kV DC (feedthroughs / base unit only – actual tolerance depends on sample and atmosphere/pressure)
    加入諮詢
    加入諮詢
  • 維修包

    維修包

    Repair kit
    Feedthrough replacement kit is used for on-site replacement of electrical mini-contact feedthroughs.
    加入諮詢
    加入諮詢
  • 標準系統

    標準系統

    Normal System
    If you need to do electrical characterization at high temperatures and in controlled atmospheres, we suggest a ProboStat™ normal system package. It includes what you need to get started with one method (e.g. 2 and 3-electrode measurements on disks). More methods can be added by adding components later on - the ProboStat™ base unit is ready for them all.
    加入諮詢
    加入諮詢
  • 液態系統

    液態系統

    Liquid Cell Accessories for ProboStat

    The ProboStat™ system can be equipped with a liquid cell accessories to measure the dielectric constant of liquids at elevated temperature.

    Typical use:

    • Dielectric measurements of liquids at RT - 200°C
    • Replaces a standard sample support tube assembly 
    • Use in combination with e.g. heating mantle 
    • ca. 0.1 – 0.5 ml measured volumes
    加入諮詢
    加入諮詢
  • 標準+系統

    標準+系統

    Normal Plus System
    System contains and does the same as the Normal system, but has more of the vulnerable parts and consumables like spring load alumina tubes and electrode contacts.
    加入諮詢
    加入諮詢