PAT-Tester-x-8
PAT-Tester-x-8 型號:PAT-Tester-x-8The PAT-Tester-x-8 potentiostat offers maximum flexibility with up to 8 channels for small scale and special purpose testing.
- Up to 8 independent channels for PAT-series and other test cells
- Each channel with fully featured potentiostat / galvanostat /
- impedance analyzer
-
Fully featured potentiostat / galvanostat / impedance analyzer with up to 8 channels for small scale and special purpose testing.
The individual test solution
The PAT-Tester-x-8 is the perfect choice for small scale and special purpose testing. It brings the same battery tester hardware and software as the PAT-Tester-i-16. However the test channels are separated into individual devices, the so-called PAT-Channel-1. Each PAT-Channel-1 features a fully equipped galvanostat / potentiostat / impedance analyzer. Up to 8 PAT-Channels may connect to one single PAT-Controller-8 which serves as the control unit for storing all measurement data and enabling communication with the EL-Software server. That way each channel of the PAT-Tester-x-8 can be controlled from any client PC in the same network via EL-Software.
The individual PAT-Channels can be placed where they are needed: on the bench, in a climate chamber, or even inside the glove box. While tailored for PAT-Cells, each PAT-Channel-1 can also connect to almost any other test cell including the ECD dilatometer, optical ECC in-situ cells and all other small format cell (e.g. coin cells, pouch cells, T-cells).PAT-Tester-x-8 setup with 6 PAT-Channels
PAT-Tester-x-8 setup with 4 PAT-Channels inside the glove box
Single-channel setup with ECD-3 Dilatometer
PAT-Tester-x-8 setup with 4 PAT-Channels and PAT-Heater-4
-
Accuracy Contour Plot
General
# Channels per device 1 to 8 Voltage -7 V to +7 V Current ±100 mA Cell connection / Electrode connection 3 electrodes plus sense wires, switch matrix ADC 2 x 24 Bit DAC 1 x 18 Bit Bandwidth ranges (Stability Factor) 500 kHz (fast) 50 kHz (medium) 5 kHz (slow) Acquisition Time (Time Base) 1 ms Internal Sample Buffer 100 GByte Computer Interface 1 GBit Ethernet Runs standalone Multiuser Voltage
Acquisition of ... Full cell voltage Both half cell voltages Auxiliary voltage Measurement Accuracy ±0.02% of FSR Control Resolution 57 μV (18 Bit) Current
Current Ranges ±100 mA ±10 mA ±1 mA ±100 μA Autorange Measurement Noise floor <1 μA @ 100mA <100 nA @ 10mA <10 nA @ 1mA <1 nA @ 100μA Measurement Accuracy ±0.05% of FSR Control Resolution 1 nA min. (18 Bit) Impedance (each channel)
Frequency range 100 μHz to 100 kHz Impedance mode PEIS and GEIS (simultaneous measurement of full- and half-cell impedances Impedance range 1 mΩ to 100 MΩ