0 like search mail home
選擇產品功能 arrow_down
>

PAT-Stand-16

PAT-Stand-16 型號:PAT-Stand-16

High througput docking station for up to 16 PAT-Cells

  • 4×4 docking station for up to 16 PAT-Cells
  • Integrated data logger for recording half cell voltages and temperature
  • Can be placed on the bench or inside temperature chamber
  • The high throughput docking station for up to 16 PAT-Cells

    Product description
    The PAT-Stand-16 is the docking station for up to 16 PAT-Cells in 4 x 4 matrix. The PAT-Stand-16 has a built-in data logger recording full and half cell voltages, cell current, tray temperature and time. The PAT-Stand-16 can be connected permanently to a usual multi-channel potentiostat (like the Biologic MPG-2 or VMP300) or battery tester (like the Maccor 4000).

    This way, the PAT-Stand-16 saves wiring effort, because it is not necessary to renew the connection of cell and potentiostat for every battery test. The PAT-Stand-16 fits nicely into a usual climate chamber (for example Binder KB53), which saves space in the lab.

    All these features make the PAT-Stand-16 with the PAT-Cells the optimal solution for high throughput battery testing.

    Schematic view of a connected PAT-Stand-16 setup

    Schematic view of a connected PAT-Stand-16 with PAT-Connect-16 for flexible wiring

    Gallery

    Testing with the PAT-Stand-16. The PAT-Stand-16 fits nicely into usual climate chambers.

    The PAT-Stand-16 can be left permanently connected to a multichannel  potentiostat. There is no need for connecting cables each time a new test is started.

    PAT-Stand-16 connected to a PAT-Connect-16.

     

  • Height 120/148 mm (without/with cells)
    Width 315 mm
    Depth 315 mm
    Weight 6.9 kg (without cells)
    Temperature resistance -20 to 70° C

     

    Name # Cell connections (PAT Socket) Operational temperature Temperature controlled cell chamber Charge / Discharge / EIS* Data Logger*** Measurements in mm (Height/Width/Length)
    PAT-Clamp-1 1 -20 - 70 ° C   Yes   21 / 62 / 80
    PAT-Stand-1 1 -20 - 70 ° C   Yes   80 / 113 / 105
    PAT-Stand-4 4 -20 - 70 ° C   Yes   84 / 119 / 301
    PAT-Heater-4 4   up to 200 ° C** Yes   230 / 265 / 400
    PAT-Stand-16 16 -20 - 70 ° C   Yes Yes 120 / 315 / 315
    PAT-Chamber-16 16   10-80 ° C Yes Yes 375 / 640 / 380

    * Compatible with any PAT series test cell
    ** 10 °C above average room temperature to 200 °C
    *** Independent data acquisition of cell data (current, full- and half-cell voltages), pressure (only PAT-Chamber-16) and temperature. EC-Link monitoring software is provided.