0 like search mail home
選擇產品功能 arrow_down
>

PAT-Stand-1

PAT-Stand-1 型號:PAT-Stand-1

The ideal docking station for individual battery testing

  • Can be placed on the bench top, inside a temperature chamber or inside a glove box
  • Docking station for a single PAT-Cell or PAT-Cell-Press
  • Saves wiring effort
  • The ideal docking station for individual battery testing

    Product description
    The PAT-Stand-1 is a docking station, which runs a single PAT-Cell or PAT-Cell-Press. It can be connected directly to a common multi-channel potentiostat (like the Biologic MPG-2 or VMP300) or battery tester (like the Maccor 4000) using 4mm banana sockets or a hardwired Sub-D socket. Therefore, the PAT-Stand-1 saves wiring effort, because it is not necessary to renew the connection of cell and potentiostat for every battery test.

    The PAT-Stand-1 fits nicely into a usual climate chamber (for example Binder KB53), which saves space in the lab. Furthermore it is small enough to be placed inside a glovebox and allows immediate functional testing of the PAT-Cell. It is even possible to perform whole battery tests inside the glovebox.

    If you want to perform individual battery tests before switching to the larger PAT-Stand-16 system, then the PAT-Stand-1 is the ideal entry docking station for you. And you can even reuse the PAT-Cell later in the larger PAT-Stand-16.

    Schematic view of a connected PAT-Stand-1 testing a PAT-Cell

    Schematic view of a connected PAT-Stand-1 testing a PAT-Cell-Press

    Gallery

  • Height 81/110 mm (without/with PAT-Cell)
    Width 105 mm
    Depth 113 mm
    Weight approx. 0.56/0.96 kg (without/with PAT-Cell)
    Temperature resistance -20 to 70° C

    Name # Cell connections (PAT Socket) Operational temperature Temperature controlled cell chamber Charge / Discharge / EIS* Data Logger*** Measurements in mm (Height/Width/Length)
    PAT-Clamp-1 1 -20 - 70 ° C   Yes   21 / 62 / 80
    PAT-Stand-1 1 -20 - 70 ° C   Yes   80 / 113 / 105
    PAT-Stand-4 4 -20 - 70 ° C   Yes   84 / 119 / 301
    PAT-Heater-4 4   up to 200 ° C** Yes   230 / 265 / 400
    PAT-Stand-16 16 -20 - 70 ° C   Yes Yes 120 / 315 / 315
    PAT-Chamber-16 16   10-80 ° C Yes Yes 375 / 640 / 380

    * Compatible with any PAT series test cell
    ** 10 °C above average room temperature to 200 °C
    *** Independent data acquisition of cell data (current, full- and half-cell voltages), pressure (only PAT-Chamber-16) and temperature. EC-Link monitoring software is provided.