  • 10 individual, independently controllable cells
  • Temperature range of -30°C to 150°C
  • Stirring rate of 350 rpm - 1200 rpm
  • For sample volumes of 1ml - 25ml
  • Optional attachments for refluxing, and working under inert conditions
  • Optional multi-infrared probes for solubility/crystallisation studies
  • Local control via colour touchscreen
  • The Integrity 10 Reaction Station enables you to conduct 10 different reactions simultaneously within the same reaction unit, each reaction being conducted within its own cell, at its own individual temperature and stir rate.

    The Integrity 10 Reaction Station is an excellent screening tool that can be used in most laboratories. It features:

    • 10 individual, independently controllable cells
    • Temperature range of -30°C to 150°C
    • Stirring rate of 350 rpm - 1200 rpm
    • For sample volumes of 1ml - 25ml
    • Optional attachments for refluxing, and working under inert conditions
    • Optional multi-infrared probes for solubility/crystallisation studies
    • Local control via colour touchscreen

      If desired, fast heating and cooling rates can be selected, with temperature ramps of between 0.1°C/min to 5°C/min. There is also a crash function for even faster temperature changes, which is ideal for kinetic determinations.

      Extreme temperature accuracy is guaranteed, with a temperature stability of ± 0.2°C and a maximum set point overshoot of 0.1°C. The temperature may be maintained either through the block itself or by using a probe within each cell's solution.

      This accuracy can be maintained over a wide temperature range of -30°C to 150°C, with precise, independently controlled temperature profiles, and homogeneous sample mixing may be assured with stirring rates of between 350rpm to 1200rpm using powerful magnetic stirrers.

      The Integrity 10 is an excellent tool for establishing ideal process conditions.

      "The Integrity 10 is perfect for my research because I'm trying to crystallise problematic compounds, so I need to change a lot of parameters for each experiment," said Paul Stainton, PhD student at the University of Lincoln. "The Reaction Station is helping to move my research along much more quickly, because it allows me to perform ten different experiments simultaneously with different parameters."
  • Number of Positions 10
    Cell Cavity Diameter 25.5mm
    Sample Volume 1 - 25ml
    Temperature Range - 30°C to + 150°C
    Possible temperature difference between adjacent positions 180°C
    Temperature Overshoot 0.1°C (maximum)
    Maximum controlled heating cooling ramp rate 0.1°C to 5°Cmin in 0.1°Cmin steps
    Stir Speed Range 350 - 1200rpm
    Viscosity Capacity Glycerine at 25°C
    Recommended Stir Bars 12 x 4.5mm (cylindrical) or 10 x 6mm (oval)
  • The Integrity 10 Reaction Station enables you to conduct 10 different reactions simultaneously within the same reaction unit, each reaction being conducted within its own cell, at its own individual temperature and stir rate.

    The Integrity 10 Reaction Station is an excellent screening tool that can be used in most laboratories. It features:

    • 10 individual, independently controllable cells
    • Temperature range of -30°C to 150°C
    • Stirring rate of 350 rpm - 1200 rpm
    • For sample volumes of 1ml - 25ml
    • Optional attachments for refluxing, and working under inert conditions
    • Optional multi-infrared probes for solubility/crystallisation studies
    • Local control via colour touchscreen

      If desired, fast heating and cooling rates can be selected, with temperature ramps of between 0.1°C/min to 5°C/min. There is also a crash function for even faster temperature changes, which is ideal for kinetic determinations.

      Extreme temperature accuracy is guaranteed, with a temperature stability of ± 0.2°C and a maximum set point overshoot of 0.1°C. The temperature may be maintained either through the block itself or by using a probe within each cell's solution.

      This accuracy can be maintained over a wide temperature range of -30°C to 150°C, with precise, independently controlled temperature profiles, and homogeneous sample mixing may be assured with stirring rates of between 350rpm to 1200rpm using powerful magnetic stirrers.

      The Integrity 10 is an excellent tool for establishing ideal process conditions.

      "The Integrity 10 is perfect for my research because I'm trying to crystallise problematic compounds, so I need to change a lot of parameters for each experiment," said Paul Stainton, PhD student at the University of Lincoln. "The Reaction Station is helping to move my research along much more quickly, because it allows me to perform ten different experiments simultaneously with different parameters."
  • Number of Positions 10
    Cell Cavity Diameter 25.5mm
    Sample Volume 1 - 25ml
    Temperature Range - 30°C to + 150°C
    Possible temperature difference between adjacent positions 180°C
    Temperature Overshoot 0.1°C (maximum)
    Maximum controlled heating cooling ramp rate 0.1°C to 5°Cmin in 0.1°Cmin steps
    Stir Speed Range 350 - 1200rpm
    Viscosity Capacity Glycerine at 25°C
    Recommended Stir Bars 12 x 4.5mm (cylindrical) or 10 x 6mm (oval)