選擇品牌

-
Neware
-
Pine Research
-
OKOndt Group
-
Novocontrol
-
Norecs
-
METERTEST
-
Microrad
-
Metrel
-
Labdex
-
SDT
-
micrux
-
AARONIA AG
-
ADASH
-
Amptek
-
AOiP
-
AstroNova
-
AWSensors
-
Automatic Research
-
BASI
-
BRS
-
Cmc
-
CTRL
-
CALMET
-
CHECKLINE
-
C-Tech
-
DV Power
-
DANATRONICS
-
ECH
-
Elsys
-
Enervac
-
Enapter
-
ELVEFLOW
-
EA Technology
-
EL-CELL
-
ENERGY SUPPORT
-
Electrothermal
-
FASTEC
-
GE
-
GMW
-
Gaskatel
-
GIUSSANI
-
Globecore
-
GREENLIGHT
-
GRZ
-
HTW
-
HIGH SENSE SOLUTIONSHTW
-
HUBER
-
Labnics
-
Ida
-
LIQUID
-
Instytut Fotonowy
-
KEHUA TECH
-
JGG
-
HVPD
-
Jenway
-
Jacomex
-
IVIUM
-
ndb
-
OZM
-
Redoxme
-
Serstech
-
SATIR
-
VacCoat
-
Zurich
- Neware
- Pine Research
- OKOndt Group
- Novocontrol
- Norecs
- METERTEST
- Microrad
- Metrel
- Labdex
- SDT
- micrux
- AARONIA AG
- ADASH
- Amptek
- AOiP
- AstroNova
- AWSensors
- Automatic Research
- BASI
- BRS
- Cmc
- CTRL
- CALMET
- CHECKLINE
- C-Tech
- DV Power
- DANATRONICS
- ECH
- Elsys
- Enervac
- Enapter
- ELVEFLOW
- EA Technology
- EL-CELL
- ENERGY SUPPORT
- Electrothermal
- FASTEC
- GE
- GMW
- Gaskatel
- GIUSSANI
- Globecore
- GREENLIGHT
- GRZ
- HTW
- HIGH SENSE SOLUTIONSHTW
- HUBER
- Labnics
- Ida
- LIQUID
- Instytut Fotonowy
- KEHUA TECH
- JGG
- HVPD
- Jenway
- Jacomex
- IVIUM
- ndb
- OZM
- Redoxme
- Serstech
- SATIR
- VacCoat
- Zurich
- Neware
- Pine Research
- OKOndt Group
- Novocontrol
- Norecs
- METERTEST
- Microrad
- Metrel
- Labdex
- SDT
- micrux
- AARONIA AG
- ADASH
- Amptek
- AOiP
- AstroNova
- AWSensors
- Automatic Research
- BASI
- BRS
- Cmc
- CTRL
- CALMET
- CHECKLINE
- C-Tech
- DV Power
- DANATRONICS
- ECH
- Elsys
- Enervac
- Enapter
- ELVEFLOW
- EA Technology
- EL-CELL
- ENERGY SUPPORT
- Electrothermal
- FASTEC
- GE
- GMW
- Gaskatel
- GIUSSANI
- Globecore
- GREENLIGHT
- GRZ
- HTW
- HIGH SENSE SOLUTIONSHTW
- HUBER
- Labnics
- Ida
- LIQUID
- Instytut Fotonowy
- KEHUA TECH
- JGG
- HVPD
- Jenway
- Jacomex
- IVIUM
- ndb
- OZM
- Redoxme
- Serstech
- SATIR
- VacCoat
- Zurich
信號調理器
Elsys > Signal Conditioning
-
Strain Gauge Amplifier
Strain Gauge AmplifierSGA-2- Internal ½- and ¼ Bridge Completion
- Two independent channels per module
- Gain x1, x10, x100
- 4-wire and 6-wire technique
- 1.5 MHz bandwidth at gain x1, x10
- Low offset voltage drift
- Low output noise
- NEW:Auto-Offset ompensation
- NEW:USB or RS485 interface for configuring all settings and read back of the actual output signal.
加入諮詢加入諮詢 -
Low Noise Amplifier
Low Noise AmplifierEL-LNA-2- Gain x10 and x100
- Differential input stage
- Input noise 4.5 nV / (Hz) 1/2
- Input impedance 1 MOhm
- Max. Output Voltage Swing
- ± 2.5 V @ no load
- ± 1.25 V @ 50 Ohm
- Bandwidth 20 MHz (G=10), 15 MHz (G=100)
加入諮詢加入諮詢 -
Universal Amplifier for Acoustic Emission Analysis
Universal Amplifier for Acoustic Emission AnalysisAE-Amp- 2 independent channels per module
- Switchable amplifier stages: 0 dB, 20 dB, 40 dB and 60 dB per channel
- 1 MHz bandwidth at gain 60 dB
- Low noise
- High voltage pulser input (500 V)
- USB / RS485 software interface for the configuration of all settings
加入諮詢加入諮詢 -
Reluctance Triggers
Reluctance TriggersEL-TRG_RThe device EL-TRIG_R is able to produce TTL-Trigger-Pulses out of analog signals from reluctance or capacitive and eddy-current sensors.
Rack System Reluctance Trigger up to 14 Channels.加入諮詢加入諮詢 -
TTL Trigger Generator and Pulse Shaper
TTL Trigger Generator and Pulse ShaperEL-PF2<p>The EL-PF2 generates clean TTL Pulses out of noisy signals. It has also the capability to delay the output signal by a precise amount of time.</p>加入諮詢加入諮詢