0 like search mail home
選擇品牌 arrow_down

代理品牌

brand
  • Thin-film Platinum InterDigitated Array Microelectrode (10/5 µm)

    Thin-film Platinum InterDigitated Array Microelectrode (10/5 µm)

    Thin-film Platinum InterDigitated Array Microelectrode (10/5 µm)
    ED-IDA5-Pt
    Thin-film Platinum InterDigitated Array Microelectrode (10/5 µm) 
    20 pairs interdigitated platinum electrodes (10/5 µm, electrode/gap) integrating reference and auxiliary electrodes. Useful for gas sensor (oxygen, nitrogen dioxide…), explosives, etc... detection. Compatible with Drop, AIO and Multi8x AIO cell.
    加入諮詢
    加入諮詢
  • Thin-film Gold InterDigitated Array Microelectrode (10/5 µm)

    Thin-film Gold InterDigitated Array Microelectrode (10/5 µm)

    Thin-film Gold InterDigitated Array Microelectrode (10/5 µm)
    ED-IDA5-Au
    20 pairs interdigitated gold electrodes (10/5 µm, electrode/gap) integrating reference and counter electrodes. Useful for thiols, uric acid, ascorbic acid, cancer biomarkers, insecticides, etc detection. Compatible with Drop, AIO and Multi8x AIO cell.
    加入諮詢
    加入諮詢
  • Thin-film Platinum InterDigitated Array Microelectrode (10/10 µm)

    Thin-film Platinum InterDigitated Array Microelectrode (10/10 µm)

    Thin-film Platinum InterDigitated Array Microelectrode (10/10 µm)
    ED-IDA1-Pt
    15 pairs interdigitated platinum electrodes (10/10 µm, electrode/gap) integrating reference and counter electrodes. Useful for gas sensor (oxygen, nitrogen dioxide…), explosives, etc... detection. Compatible with Drop, AIO and Multi8x AIO cell.
    加入諮詢
    加入諮詢
  • Thin-film Gold InterDigitated Array Microelectrode (10/10 µm)

    Thin-film Gold InterDigitated Array Microelectrode (10/10 µm)

    Thin-film Gold InterDigitated Array Microelectrode (10/10 µm)
    ED-IDA1-Au
    15 pairs interdigitated gold electrodes (10/10 µm, electrode/gap) integrating reference and auxiliary electrodes. Useful for thiols, uric acid, ascorbic acid, cancer biomarkers, insecticides, etc... detection. Compatible with Drop, AIO and Multi8x AIO cell.
    加入諮詢
    加入諮詢
  • Thin-film Platinum InterDigitated Electrode (5/5 µm)

    Thin-film Platinum InterDigitated Electrode (5/5 µm)

    Thin-film Platinum InterDigitated Electrode (5/5 µm)
    ED-IDE3-Pt
    180 pairs of interdigitated platinum electrodes (5/5 µm, electrode/gap). Useful for optics, electrochemistry, scanning electrochemistry microscopy, etc. Compatible with Drop, AIO and Multi8x AIO cell.
    加入諮詢
    加入諮詢
  • Thin-film Gold InterDigitated Electrode (5/5 µm)

    Thin-film Gold InterDigitated Electrode (5/5 µm)

    Thin-film Gold InterDigitated Electrode (5/5 µm)
    ED-IDE3-Au
    180 pairs of interdigitated gold electrodes (5/5 µm, electrode/gap). Useful for optical and electrochemical (impedance) studies, spectroelectrochemistry, etc. Compatible with Drop, AIO and Multi8x AIO cell.
    加入諮詢
    加入諮詢
  • Thin-film Platinum InterDigitated Electrode (10/5 µm)

    Thin-film Platinum InterDigitated Electrode (10/5 µm)

    Thin-film Platinum InterDigitated Electrode (10/5 µm)
    ED-IDE2-Pt
    120 pairs of interdigitated platinum electrodes (10/5 µm, electrode/gap). Useful for optics, electrochemistry (impedance, conductivity...), scanning electrochemistry microscopy, etc. Compatible with Drop, AIO and Multi8x AIO cell.
    加入諮詢
    加入諮詢
  • Thin-film Gold InterDigitated Electrode (10/5 µm)

    Thin-film Gold InterDigitated Electrode (10/5 µm)

    Thin-film Gold InterDigitated Electrode (10/5 µm)
    ED-IDE2-Au
    120 pairs of interdigitated gold electrodes (10/5 µm, electrode/gap). Useful for optical and electrochemical (impedance) studies, spectroelectrochemistry, etc. Compatible with Drop, AIO and Multi8x AIO cell.
    加入諮詢
    加入諮詢
  • Thin-film Platinum InterDigitated Electrode (10/10 µm)

    Thin-film Platinum InterDigitated Electrode (10/10 µm)

    Thin-film Platinum InterDigitated Electrode (10/10 µm)
    ED-IDE1-Pt
    90 pairs of interdigitated platinum electrodes (10/10 µm, electrode/gap). Useful for optical and electrochemical (impedance) studies, scanning electrochemistry microscopy, etc. Compatible with Drop, AIO and Multi8x AIO cell.
    加入諮詢
    加入諮詢
  • Thin-film Gold InterDigitated Electrode (10/10 µm)

    Thin-film Gold InterDigitated Electrode (10/10 µm)

    Thin-film Gold InterDigitated Electrode (10/10 µm)
    ED-IDE1-Au
    90 pairs of interdigitated gold electrodes (10/10 µm, electrode/gap). Useful for optical and electrochemical (impedance) studies, spectroelectrochemistry, etc. Compatible with Drop, AIO and Multi8x AIO cell.
    加入諮詢
    加入諮詢