- Neware
- Pine Research
- OKOndt Group
- Novocontrol
- Norecs
- METERTEST
- Microrad
- Metrel
- Labdex
- SDT
- micrux
- AARONIA AG
- ADASH
- Amptek
- AOiP
- AstroNova
- AWSensors
- Automatic Research
- BASI
- BRS
- Cmc
- CTRL
- CALMET
- CHECKLINE
- C-Tech
- DV Power
- DANATRONICS
- ECH
- Elsys
- Enervac
- Enapter
- ELVEFLOW
- EA Technology
- EL-CELL
- ENERGY SUPPORT
- Electrothermal
- FASTEC
- GE
- GMW
- Gaskatel
- GIUSSANI
- Globecore
- GREENLIGHT
- GRZ
- HTW
- HIGH SENSE SOLUTIONSHTW
- HUBER
- Labnics
- Ida
- LIQUID
- Instytut Fotonowy
- KEHUA TECH
- JGG
- HVPD
- Jenway
- Jacomex
- IVIUM
- ndb
- OZM
- Redoxme
- Serstech
- SATIR
- VacCoat
- Zurich
- Neware
- Pine Research
- OKOndt Group
- Novocontrol
- Norecs
- METERTEST
- Microrad
- Metrel
- Labdex
- SDT
- micrux
- AARONIA AG
- ADASH
- Amptek
- AOiP
- AstroNova
- AWSensors
- Automatic Research
- BASI
- BRS
- Cmc
- CTRL
- CALMET
- CHECKLINE
- C-Tech
- DV Power
- DANATRONICS
- ECH
- Elsys
- Enervac
- Enapter
- ELVEFLOW
- EA Technology
- EL-CELL
- ENERGY SUPPORT
- Electrothermal
- FASTEC
- GE
- GMW
- Gaskatel
- GIUSSANI
- Globecore
- GREENLIGHT
- GRZ
- HTW
- HIGH SENSE SOLUTIONSHTW
- HUBER
- Labnics
- Ida
- LIQUID
- Instytut Fotonowy
- KEHUA TECH
- JGG
- HVPD
- Jenway
- Jacomex
- IVIUM
- ndb
- OZM
- Redoxme
- Serstech
- SATIR
- VacCoat
- Zurich
-
專門對合成和生物燃料生產線常見的四種原子進行可靠、準確的分析。
在這個強大且不斷發展的全球產業結構中,與合成燃料或生物燃料生產的相關行業扮演著重要的角色。對於這類的衍生產品,BWB Technologies 提供了一種混合火焰光度計,我們將其命名為 Syn Fuels。
BWB SYN FUELS 火焰光度計是第一款也是唯一一款能夠同時偵測並顯示所有 4 種元素的 4 通道火焰光度計。BWB SYN FUELS 是一款高品質、高性能的儀器,採用現代技術來提高準確性和穩定性,同時顯著縮短分析時間。
BWB SYN FUELS 火焰光度計的流體處理部分,採用了專有的工程熱塑性塑料,這些熱塑性塑料具有高度耐化學性,可承受合成燃料生產設施中使用的溶劑。
我們在全球的客戶經過統計,大多數是甜菜或甘蔗精煉廠購買 BWB Sugar ,而生物轉化工廠則購買 Syn Fuels FES。
產品特點:
- 同時偵測並顯示所有 4 種分析元素。
- 「IRS」(內部參考標準)銫或鋰選項。
- 直覺的使用者介面真正易於使用。
- 顯示提示引導操作。
- 內建空氣壓縮機。
- 含括基本儀器所需器具,可協助您入門。
- 透過電腦連結共享數據。
- 操作員獨立確定結果。
- 使用者可選4 個測量單位。
- 使用者可選擇小數位。
- 選購的整合式印表機使用現成的紙張(新增選項)。
- 提供 IQ、OQ、PQ 基於網路的認證。
- 校正 Ca 以消除高濃度 Na 的干擾。
-
Sample rate
2 – 3.5ml/min
Tubing materials
PTFE and Teflon
Required desk space for Instrument
50cm (H) x 45cm (W) x 45cm (D)
*For Safety reasons the Flame
photometer requires 1m of
unobstructed space above
to allow dissipation of heat from the chimney.Instrument size
Syn Fuels Flame Photometer
51cm (H) x 39cm (W) x 35cm (D)
(20in x 15in x 14in)Shipping
65cm (H) x 49cm (W) x 43cm (D)
(25in x 19in x 17in)Weight
Syn Fuels Flame Photometer – 14kg (30.8lbs)
Shipping – 25kg (55.1lbs)
Power requirements
100V – 250V AC at 50 or 60Hz
Readout
LCD, four line, alpha numeric, back lit.
Optimal range
Single point calibration
Na 0.1 – 60ppm
K 0.05 – 100ppm
Li 0.05 – 50ppm
Ca 1.0 – 100ppm
Multi Point Calibration
Na 0.1 – 1000ppm
K 0.05 – 1000ppm
Li 0.05 – 1000ppm
Ca 1.0 – 1000ppm
Reproducibility
<1% Coefficient of variability for 20 consecutive
samples over ten minutes at concentrations of 100ppm or less.
(After instrument stabilisation).Specificity
Na/K/Li = <1% to each other when
equal in concentration at <100ppmLimit of detection (LOD) and limit
of quantification (LOQ) displayedLOD LOQ
Na – 0.03ppm Na – 0.1ppm
K – 0.02ppm K – 0.05ppm
Li – 0.02ppm Li – 0.05ppm
Ca – 0.3ppm Ca – 1ppm
Time to stability
Less than 15 seconds after sample is introduced
into the flameIons measured
Simultaneous measurement of Na, K, Li, Ca
Interfaces
USB
0-2.5 volt output (based on sample
concentration linked to element of users choice)
Optional 4-20mA output in place of the above
Optional integrated printer.CSV and .PDF generated
reports and files via FP-PC software
Collection Cup fitted as standard allowing live readingRecommended minimum warm uptime based
on ambient temperature21°C – 25 minutes
Fuel requirement
Propane, Butane or Natural Gas* regulated to 19Bar.
Flow rate of 0.4l/min*with modifications. BWB Technologies
recommends either Propane or Butane for optimum results. -
- Simultaneous detection and display of all 4 atoms of interest
- “IRS” (Internal Reference Standard) caesium or lithium option
- Intuitive user interface for true ease of use
- Display prompts step by step operation
- Built-in air compressor
- Solutions and labware included
- Data sharing via pc link
- Operator independent determination of results
- 4 user selectable units of measure
- User selectable decimal places
- Optional integrated printer uses readily available paper (added option)
- IQ, OQ, PQ web-based certification available
- Correction of Ca for the interference from high levels of Na
-
Sample rate
2 – 3.5ml/min
Tubing materials
PTFE and Teflon
Required desk space for Instrument
50cm (H) x 45cm (W) x 45cm (D)
*For Safety reasons the Flame
photometer requires 1m of
unobstructed space above
to allow dissipation of heat from the chimney.Instrument size
Syn Fuels Flame Photometer
51cm (H) x 39cm (W) x 35cm (D)
(20in x 15in x 14in)Shipping
65cm (H) x 49cm (W) x 43cm (D)
(25in x 19in x 17in)Weight
Syn Fuels Flame Photometer – 14kg (30.8lbs)
Shipping – 25kg (55.1lbs)
Power requirements
100V – 250V AC at 50 or 60Hz
Readout
LCD, four line, alpha numeric, back lit.
Optimal range
Single point calibration
Na 0.1 – 60ppm
K 0.05 – 100ppm
Li 0.05 – 50ppm
Ca 1.0 – 100ppm
Multi Point Calibration
Na 0.1 – 1000ppm
K 0.05 – 1000ppm
Li 0.05 – 1000ppm
Ca 1.0 – 1000ppm
Reproducibility
<1% Coefficient of variability for 20 consecutive
samples over ten minutes at concentrations of 100ppm or less.
(After instrument stabilisation).Specificity
Na/K/Li = <1% to each other when
equal in concentration at <100ppmLimit of detection (LOD) and limit
of quantification (LOQ) displayedLOD LOQ
Na – 0.03ppm Na – 0.1ppm
K – 0.02ppm K – 0.05ppm
Li – 0.02ppm Li – 0.05ppm
Ca – 0.3ppm Ca – 1ppm
Time to stability
Less than 15 seconds after sample is introduced
into the flameIons measured
Simultaneous measurement of Na, K, Li, Ca
Interfaces
USB
0-2.5 volt output (based on sample
concentration linked to element of users choice)
Optional 4-20mA output in place of the above
Optional integrated printer.CSV and .PDF generated
reports and files via FP-PC software
Collection Cup fitted as standard allowing live readingRecommended minimum warm uptime based
on ambient temperature21°C – 25 minutes
Fuel requirement
Propane, Butane or Natural Gas* regulated to 19Bar.
Flow rate of 0.4l/min*with modifications. BWB Technologies
recommends either Propane or Butane for optimum results.