選擇品牌
- Neware
- Pine Research
- OKOndt Group
- Novocontrol
- Norecs
- METERTEST
- Microrad
- Metrel
- Labdex
- SDT
- micrux
- AARONIA AG
- ADASH
- Amptek
- AOiP
- AstroNova
- AWSensors
- Automatic Research
- BASI
- BRS
- BWB Technologies
- Cmc
- CTRL
- CALMET
- CHECKLINE
- Coxem
- C-Tech
- DV Power
- DANATRONICS
- ECH
- Elsys
- Enervac
- Enapter
- ELVEFLOW
- EA Technology
- EL-CELL
- ENERGY SUPPORT
- Electrothermal
- FASTEC
- GE
- GMW
- Gaskatel
- GIUSSANI
- Globecore
- GREENLIGHT
- GRZ
- HTW
- HIGH SENSE SOLUTIONSHTW
- HUBER
- Labnics
- Ida
- LIQUID
- Instytut Fotonowy
- KEHUA TECH
- JGG
- HVPD
- Jenway
- Jacomex
- IVIUM
- ndb
- OZM
- Redoxme
- Serstech
- SATIR
- VacCoat
- Zurich
- Neware
- Pine Research
- OKOndt Group
- Novocontrol
- Norecs
- METERTEST
- Microrad
- Metrel
- Labdex
- SDT
- micrux
- AARONIA AG
- ADASH
- Amptek
- AOiP
- AstroNova
- AWSensors
- Automatic Research
- BASI
- BRS
- BWB Technologies
- Cmc
- CTRL
- CALMET
- CHECKLINE
- Coxem
- C-Tech
- DV Power
- DANATRONICS
- ECH
- Elsys
- Enervac
- Enapter
- ELVEFLOW
- EA Technology
- EL-CELL
- ENERGY SUPPORT
- Electrothermal
- FASTEC
- GE
- GMW
- Gaskatel
- GIUSSANI
- Globecore
- GREENLIGHT
- GRZ
- HTW
- HIGH SENSE SOLUTIONSHTW
- HUBER
- Labnics
- Ida
- LIQUID
- Instytut Fotonowy
- KEHUA TECH
- JGG
- HVPD
- Jenway
- Jacomex
- IVIUM
- ndb
- OZM
- Redoxme
- Serstech
- SATIR
- VacCoat
- Zurich
PFP7 Industrial Flame Photometer
PFP7 Industrial Flame Photometer 型號:PFP7
• Designed for industrial analysis
• Supplied with Na, K, Li, Ba and Ca filters
• Low temperature, single channel
• Flame failure safety system
• Operates with propane, butane, natural gas or LPG
• Supplied with Na, K, Li, Ba and Ca filters
• Low temperature, single channel
• Flame failure safety system
• Operates with propane, butane, natural gas or LPG
-
The PFP7 is a low temperature, single channel flame photometer that is designed for the routine determination of sodium, potassium, calcium, barium and lithium concentrations. The flame failure safety system makes these products ideal for use in industrial and educational environments. The use of fine and coarse sensitivity controls allows for accurate measurements each and every time.
-
Parameter
PFP7
Range
0 to 199.9ppm
Limits of detection Na
0.2ppm
K
0.2ppm
Li
0.25ppm
Ca
15ppm
Ba
30ppm
Reproducibility
<1% coefficient of variation for 20 consecutive samples using 10ppm Na set to read 50
Linearity
< 2% error when 3ppm Na/K and 5ppm Li are set to read 100
Stability
< 2% drift over 5min when continuously aspirating 10ppm sample set to 50.0. Specificity Interference from Na/K and Li equal in concentration to test element will be <0.5%
Recorder output
Nominal 1.00V for a reading of 100.0
Electrical supply
90-125V or 190-250V @50/60Hz
Air supply
Moisture and oil free, 6 litre/min @ 14psi
Fuel
Propane, butane, natural gas or LPG
Size (w x d x h)
420 x 360 x 300mm
Weight
8kg