選擇品牌
- Neware
- Pine Research
- OKOndt Group
- Novocontrol
- Norecs
- METERTEST
- Microrad
- Metrel
- Labdex
- SDT
- micrux
- AARONIA AG
- ADASH
- Amptek
- AOiP
- AstroNova
- AWSensors
- Automatic Research
- BASI
- BRS
- Cmc
- CTRL
- CALMET
- CHECKLINE
- C-Tech
- DV Power
- DANATRONICS
- ECH
- Elsys
- Enervac
- Enapter
- ELVEFLOW
- EA Technology
- EL-CELL
- ENERGY SUPPORT
- Electrothermal
- FASTEC
- GE
- GMW
- Gaskatel
- GIUSSANI
- Globecore
- GREENLIGHT
- GRZ
- HTW
- HIGH SENSE SOLUTIONSHTW
- HUBER
- Labnics
- Ida
- LIQUID
- Instytut Fotonowy
- KEHUA TECH
- JGG
- HVPD
- Jenway
- Jacomex
- IVIUM
- ndb
- OZM
- Redoxme
- Serstech
- SATIR
- VacCoat
- Zurich
- Neware
- Pine Research
- OKOndt Group
- Novocontrol
- Norecs
- METERTEST
- Microrad
- Metrel
- Labdex
- SDT
- micrux
- AARONIA AG
- ADASH
- Amptek
- AOiP
- AstroNova
- AWSensors
- Automatic Research
- BASI
- BRS
- Cmc
- CTRL
- CALMET
- CHECKLINE
- C-Tech
- DV Power
- DANATRONICS
- ECH
- Elsys
- Enervac
- Enapter
- ELVEFLOW
- EA Technology
- EL-CELL
- ENERGY SUPPORT
- Electrothermal
- FASTEC
- GE
- GMW
- Gaskatel
- GIUSSANI
- Globecore
- GREENLIGHT
- GRZ
- HTW
- HIGH SENSE SOLUTIONSHTW
- HUBER
- Labnics
- Ida
- LIQUID
- Instytut Fotonowy
- KEHUA TECH
- JGG
- HVPD
- Jenway
- Jacomex
- IVIUM
- ndb
- OZM
- Redoxme
- Serstech
- SATIR
- VacCoat
- Zurich
PFP7/C Research Flame Photometer
PFP7/C Research Flame Photometer 型號:PFP7
• Designed for research applications
• Supplied with Na, K and Li filters
• Low temperature, single channel
• Flame failure safety system
• Operates with propane, butane, natural gas or LPG
• Supplied with Na, K and Li filters
• Low temperature, single channel
• Flame failure safety system
• Operates with propane, butane, natural gas or LPG
-
The PFP7/C is a low temperature, single channel flame photometer that is specifically designed for use in research applications for the determination of sodium, potassium and lithium.
The in-built lineariser circuitry of the PFP7/C enables readings of both sodium and potassium to be displayed directly in mmol/l. -
Parameter PFP7/C Range 120 to 160mmol/l Na, 0 to 10.0mmol/l K Limits of detection Na 0.2ppm K 0.2ppm Li 0.25ppm Reproducibility <1% coefficient of variation for 20 consecutive samples using 10ppm Na set to read 50 Linearity < 2% error when 3ppm Na/K and 5ppm Li are set to read 100 Stability < 2% drift over 5min when continuously aspirating 10ppm sample set to 50.0. Specificity Interference from Na/K and Li equal in concentration to test element will be <0.5% Recorder output Nominal 1.00V for a reading of 100.0 Electrical supply 90–125V or 190–250V @50/60Hz Air supply Moisture and oil free, 6 litre/min @ 14psi Fuel Propane, butane, natural gas or LPG Size (w x d x h) 420 x 360 x 300mm Weight 8kg