選擇品牌

-
AARONIA AG
-
ADASH
-
Amptek
-
AOiP
-
AstroNova
-
Automatic Research
-
AWSensors
-
BASI
-
BRS
-
CALMET
-
CHECKLINE
-
Cmc
-
C-Tech
-
CTRL
-
DANATRONICS
-
DV Power
-
EA Technology
-
ECH
-
EL-CELL
-
Electrothermal
-
Elsys
-
ELVEFLOW
-
Enapter
-
ENERGY SUPPORT
-
Enervac
-
FASTEC
-
Gaskatel
-
GE
-
GIUSSANI
-
Globecore
-
GMW
-
GREENLIGHT
-
GRZ
-
HIGH SENSE SOLUTIONSHTW
-
HTW
-
HUBER
-
HVPD
-
Ida
-
Instytut Fotonowy
-
IVIUM
-
Jacomex
-
Jenway
-
JGG
-
KEHUA TECH
-
Labdex
-
Labnics
-
LIQUID
-
METERTEST
-
Metrel
-
Microrad
-
micrux
-
ndb
-
Neware
-
Norecs
-
Novocontrol
-
OKOndt Group
-
OZM
-
Pine Research
-
Redoxme
-
SATIR
-
SDT
-
Serstech
-
VacCoat
-
Zurich
- AARONIA AG
- ADASH
- Amptek
- AOiP
- AstroNova
- Automatic Research
- AWSensors
- BASI
- BRS
- CALMET
- CHECKLINE
- Cmc
- C-Tech
- CTRL
- DANATRONICS
- DV Power
- EA Technology
- ECH
- EL-CELL
- Electrothermal
- Elsys
- ELVEFLOW
- Enapter
- ENERGY SUPPORT
- Enervac
- FASTEC
- Gaskatel
- GE
- GIUSSANI
- Globecore
- GMW
- GREENLIGHT
- GRZ
- HIGH SENSE SOLUTIONSHTW
- HTW
- HUBER
- HVPD
- Ida
- Instytut Fotonowy
- IVIUM
- Jacomex
- Jenway
- JGG
- KEHUA TECH
- Labdex
- Labnics
- LIQUID
- METERTEST
- Metrel
- Microrad
- micrux
- ndb
- Neware
- Norecs
- Novocontrol
- OKOndt Group
- OZM
- Pine Research
- Redoxme
- SATIR
- SDT
- Serstech
- VacCoat
- Zurich
PFP7/C Research Flame Photometer
PFP7/C Research Flame Photometer 型號:PFP7
• Designed for research applications
• Supplied with Na, K and Li filters
• Low temperature, single channel
• Flame failure safety system
• Operates with propane, butane, natural gas or LPG
• Supplied with Na, K and Li filters
• Low temperature, single channel
• Flame failure safety system
• Operates with propane, butane, natural gas or LPG
-
The PFP7/C is a low temperature, single channel flame photometer that is specifically designed for use in research applications for the determination of sodium, potassium and lithium.
The in-built lineariser circuitry of the PFP7/C enables readings of both sodium and potassium to be displayed directly in mmol/l. -
Parameter PFP7/C Range 120 to 160mmol/l Na, 0 to 10.0mmol/l K Limits of detection Na 0.2ppm K 0.2ppm Li 0.25ppm Reproducibility <1% coefficient of variation for 20 consecutive samples using 10ppm Na set to read 50 Linearity < 2% error when 3ppm Na/K and 5ppm Li are set to read 100 Stability < 2% drift over 5min when continuously aspirating 10ppm sample set to 50.0. Specificity Interference from Na/K and Li equal in concentration to test element will be <0.5% Recorder output Nominal 1.00V for a reading of 100.0 Electrical supply 90–125V or 190–250V @50/60Hz Air supply Moisture and oil free, 6 litre/min @ 14psi Fuel Propane, butane, natural gas or LPG Size (w x d x h) 420 x 360 x 300mm Weight 8kg