- Neware
- Pine Research
- OKOndt Group
- Novocontrol
- Norecs
- METERTEST
- Microrad
- Metrel
- Labdex
- SDT
- micrux
- AARONIA AG
- ADASH
- Amptek
- AOiP
- AstroNova
- AWSensors
- Automatic Research
- BASI
- BRS
- BWB Technologies
- Cmc
- CTRL
- CALMET
- CHECKLINE
- Coxem
- C-Tech
- DV Power
- DANATRONICS
- ECH
- Elsys
- Enervac
- Enapter
- ELVEFLOW
- EA Technology
- EL-CELL
- ENERGY SUPPORT
- Electrothermal
- FASTEC
- GE
- GMW
- Gaskatel
- GIUSSANI
- Globecore
- GREENLIGHT
- GRZ
- HTW
- HIGH SENSE SOLUTIONSHTW
- HUBER
- Labnics
- Ida
- LIQUID
- Instytut Fotonowy
- KEHUA TECH
- JGG
- HVPD
- Jenway
- Jacomex
- IVIUM
- ndb
- OZM
- Redoxme
- Serstech
- SATIR
- VacCoat
- Zurich
- Neware
- Pine Research
- OKOndt Group
- Novocontrol
- Norecs
- METERTEST
- Microrad
- Metrel
- Labdex
- SDT
- micrux
- AARONIA AG
- ADASH
- Amptek
- AOiP
- AstroNova
- AWSensors
- Automatic Research
- BASI
- BRS
- BWB Technologies
- Cmc
- CTRL
- CALMET
- CHECKLINE
- Coxem
- C-Tech
- DV Power
- DANATRONICS
- ECH
- Elsys
- Enervac
- Enapter
- ELVEFLOW
- EA Technology
- EL-CELL
- ENERGY SUPPORT
- Electrothermal
- FASTEC
- GE
- GMW
- Gaskatel
- GIUSSANI
- Globecore
- GREENLIGHT
- GRZ
- HTW
- HIGH SENSE SOLUTIONSHTW
- HUBER
- Labnics
- Ida
- LIQUID
- Instytut Fotonowy
- KEHUA TECH
- JGG
- HVPD
- Jenway
- Jacomex
- IVIUM
- ndb
- OZM
- Redoxme
- Serstech
- SATIR
- VacCoat
- Zurich
P-5
Two-pole Voltage Tester 型號:P-5-
Main functions and attributes of the P-line instruments:
- automatic voltage test up to 1000 V AC/DC,
- optical indication by a LED bar and additional LCD display,
- sound indication when dangerous voltage levels of 50 V AC and 120 V DC are exceeded,
- RCD trip test with switchable load,
- automatic continuity test upon connection to the object,
- 2-pole test of phase rotation direction,
- single-pole indication of 100 V presence,
- resistance measurement up to 1999 Ω,
- HOLD function for freezing the measurement results,
- robust, two-component housing protecting from mechanical damages and impacts,
- integrated torch light and backlit display for tests in poorly lit areas,
- IP65 ingress protection guarantees protection against dust and water,
- safety provided by measuring class compliant with CAT IV 600 V and CAT III 1000 V.
-
AC and DC voltage measurements:
- indication on the analog bargraph: 12, 24, 50, 120, 230, 400, ≥690 V,
- displaying on the backlighted LCD up to 1000 V,
- determination of alternating voltage or direct voltage polarization.
Continuity test:
- indication for resistance R ≤ 400 kΩ
- optical and acoustic indication
Resistance measurements:
- measurement range up to 1999 Ω
Phase sequence test:
- phase sequence indication for voltage U> 100 V.
Single-pole phase test:
- optical and acoustic indication for voltage U> 100 V.
RCD trip test:
- RCD test for IΔn ≤30 mA.
Display: backlight LCD 3½ digits, counts 1999.
HOLD function: HOLD button to freeze the result on the diode line and LCD display.
Operating frequency range: 16..400 Hz.
Measurement category in acc. to EN 61010-1: CAT III 1000 V, IV 600 V.
Ingress protection in acc. to EN 60529: IP65.
Type of insulation acc. to EN 61010-1: double, class II.
Power supply: 2 x LR03 AAA 1,5 V (recommended alkaline cells).
Working / storage temperature: -15..+55°C / -20..+70°C.
Dimensions: 275 x 82 x 36 mm.
Weight without batteries: 267 g.
Measuring tips: Ø2 mm/ Ø 4 mm/dł. 4mm (GS38).
Backlight measuring place: integrated torch.
Standard compliance: EN 61326-1, EN 61326-2-2, EN 61010-1, EN 61243-3.