選擇品牌
- Neware
- Pine Research
- OKOndt Group
- Novocontrol
- Norecs
- METERTEST
- Microrad
- Metrel
- Labdex
- SDT
- micrux
- AARONIA AG
- ADASH
- Amptek
- AOiP
- AstroNova
- AWSensors
- Automatic Research
- BASI
- BRS
- Cmc
- CTRL
- CALMET
- CHECKLINE
- C-Tech
- DV Power
- DANATRONICS
- ECH
- Elsys
- Enervac
- Enapter
- ELVEFLOW
- EA Technology
- EL-CELL
- ENERGY SUPPORT
- Electrothermal
- FASTEC
- GE
- GMW
- Gaskatel
- GIUSSANI
- Globecore
- GREENLIGHT
- GRZ
- HTW
- HIGH SENSE SOLUTIONSHTW
- HUBER
- Labnics
- Ida
- LIQUID
- Instytut Fotonowy
- KEHUA TECH
- JGG
- HVPD
- Jenway
- Jacomex
- IVIUM
- ndb
- OZM
- Redoxme
- Serstech
- SATIR
- VacCoat
- Zurich
- Neware
- Pine Research
- OKOndt Group
- Novocontrol
- Norecs
- METERTEST
- Microrad
- Metrel
- Labdex
- SDT
- micrux
- AARONIA AG
- ADASH
- Amptek
- AOiP
- AstroNova
- AWSensors
- Automatic Research
- BASI
- BRS
- Cmc
- CTRL
- CALMET
- CHECKLINE
- C-Tech
- DV Power
- DANATRONICS
- ECH
- Elsys
- Enervac
- Enapter
- ELVEFLOW
- EA Technology
- EL-CELL
- ENERGY SUPPORT
- Electrothermal
- FASTEC
- GE
- GMW
- Gaskatel
- GIUSSANI
- Globecore
- GREENLIGHT
- GRZ
- HTW
- HIGH SENSE SOLUTIONSHTW
- HUBER
- Labnics
- Ida
- LIQUID
- Instytut Fotonowy
- KEHUA TECH
- JGG
- HVPD
- Jenway
- Jacomex
- IVIUM
- ndb
- OZM
- Redoxme
- Serstech
- SATIR
- VacCoat
- Zurich
多通道恒電位/恒電流儀
Multi-channel Potentiostat/Galvanostat Analyzer 型號:IviumnStat- 每個機箱最多可安裝 8 個模組/16 個通道(可堆疊至 64 個通道)。
- 模組可混合搭配,以實現最大的多功能性。
- 每個通道標配的阻抗頻率範圍為:10µHz - 250kHz(可選 1MHz)。
-
- 每個機箱最多可安裝 8 個模組/16 個通道(可堆疊至 64 個通道)。
- 模組可混合搭配,以實現最大的多功能性。
- 每個通道標配的阻抗頻率範圍為:10µHz - 250kHz(可選 1MHz)。
應用範圍廣
該儀器應用範圍廣泛,如 : 電池/燃料電池測試、電極開發、生物技術和其它電化學研究應用。
完整的解決方案
Ivium-n-Stat 提供完整的解決方案。主機包括內建的高性能頻率響應分析儀、低至 100 pA 全量程的低電流測量能力以及所有標準電化學技術。所有測量和數據處理均可所提供的軟體中執行(適用於基於 Windows 的 PC)。
安全性
儀器的最大電流或電位可由操作員設定。這樣就可以保護珍貴的樣品,防止出現不安全的情況。
自動化
提供多個類比和數位輸入/輸出埠,用於監測和控制外部設備。此一功能都已獲得完整開發並整合到軟體中。
擴展性
每個通道都可通過各種選件和模組(取決於兼容性)進行擴展,如功率放大器、多路復用器等。
硬體:- 自動電流範圍選擇: 100pA 至 10A/1mV 至 10V。
- 自動變量的雜訊濾波器和恒電位/恆電流儀穩定性設定。
- 同時採集電流/電位和外部類比信號。。
- 即時數據顯示高達 3,000 pnts/s。高達300,000 pnts/s 的取樣儲存在儀器記憶體中。
- 可應用的掃描速率: 1µV/s 至 10,000V/s。
- 最小間隔時間:3.33µs(0.125μs 解析度)。
- 通過自動調整濾波器、增益放大器和直流減去對結果進行最佳化。
- 使用者可選擇浮動操作。
通道配置
單通道模塊:- ±2.5A / ±10V(可選購 BiStat )
- ±2.5A / ±10V(可選購 BiStat)
- ±5A / ±10V(可選購 BiStat)
- ±10A / ±5V
- ±20A / ±2V
- ±2A/±20V
- ±1A/±50V
雙通道模組:- 2 x ±1A / ±20V
- 2 x ±2.5A / ±10V
機箱:- 40A 適合所有通道配置。
- -每個機箱可容納 8 個模組/16 個通道。
- -最多可堆疊 64 個通道。
軟體 :
Ivium-n-Stat 通過 Ivium 自備的 IviumSoft 軟體進行控制。這款功能多樣、直觀易用的軟體可用於儀器控制、數據管理和分析等。IviumSoft 軟體還可與 LabVIEWTM、C++、Delphi 等軟體連接並由其控制。每台儀器都標配全套 IviumSoft 軟體。- 單獨控制不同通道。
- 同時控制所有通道。
- 同步啟動。
- 不同通道的數據可分別繪製或繪製在一張圖表中。
可選模組比較
-
-
- Up to 8 modules/16 channels per frame (stackable up to 64 channels) can be installed.
- Modules can be mix and matched for maximum versatility.
- Integrated impedance analyser in each channel as standard: 10µHz - 250kHz (1MHz optional).
Dedicated application
The instrument is designed for a wide range of applications, such as battery/fuel cell-testing, electrode development, biotechnology and other Electrochemical Research applications.
Complete solution
The Ivium-n-Stat offers a complete package. The hardware includes a built-in high-performance Frequency Response Analyser, low current measurement possibility down to 100pA full-scale, and all the standard electrochemical techniques. All measurement and dataprocessing software is included (for Windows based PCs).
Safety
The maximum current or potential of the instrument can be defined by the operator. Thus valuable samples may be protected, and unsafe situations prevented.
Automation
Multiple analog and digital input & output ports are available for monitoring & control of peripheral equipment. This functionality is fully integrated in the software.
Expandibility
Each channel can be expanded with various options and modules (depending on the compatibility), such as a power booster, multiplexer, etc.
Hardware- Automatic current range selection: 100pA to 10A/1mV to 10V.
- Automatic variable noise filter and potentiostat/galvanostat stability settings.
- Simultaneous acquisition of current/potential and peripheral analog signals.
- Real time data display up to 3,000 pnts/s. Acquisition up to 300,000 pnts/s is stored in instrument memory.
- Applicable scanrates: 1µV/s to 10,000V/s.
- Minimum interval time: 3.33µs (0.125µs resolution).
- Result optimisation by automated tuned filters, gain amplifiers and DC-subtraction.
- User selectable floating operation.
Channel Configurations
Single-channel modules:- ±2.5A / ±10V (with BiStat optional)
- ±5A / ±10V (with BiStat optional)
- ±10A / ±5V
- ±20A / ±2V
- ±2A / ±20V
- ±1A / ±50V
Dual-channel modules:- 2 x ±1A / ±20V
- 2 x ±2.5A / ±10V
- 40A to fit all channel configurations.
- 8 modules/16 channels per frame.
- Stackable up to 64 channels.
Software
The Ivium-n-Stat is controlled via Ivium’s own IviumSoft. This versatile, yet intuitive software, allows instrument control, data management and analysis, etc. IviumSoft can also interface with and be controlled from LabVIEWTM, C++, Delphi, etc. A full suite of IviumSoft is included as standard with each instrument.Control of separate channels individually- Control of separate channels individually
- All channels simultaneously
- Synchronous start
- Data from different channels plotted individually or in 1 single graph
Available modules
-