- Neware
- Pine Research
- OKOndt Group
- Novocontrol
- Norecs
- METERTEST
- Microrad
- Metrel
- Labdex
- SDT
- micrux
- AARONIA AG
- ADASH
- Amptek
- AOiP
- AstroNova
- AWSensors
- Automatic Research
- BASI
- BRS
- Cmc
- CTRL
- CALMET
- CHECKLINE
- C-Tech
- DV Power
- DANATRONICS
- ECH
- Elsys
- Enervac
- Enapter
- ELVEFLOW
- EA Technology
- EL-CELL
- ENERGY SUPPORT
- Electrothermal
- FASTEC
- GE
- GMW
- Gaskatel
- GIUSSANI
- Globecore
- GREENLIGHT
- GRZ
- HTW
- HIGH SENSE SOLUTIONSHTW
- HUBER
- Labnics
- Ida
- LIQUID
- Instytut Fotonowy
- KEHUA TECH
- JGG
- HVPD
- Jenway
- Jacomex
- IVIUM
- ndb
- OZM
- Redoxme
- Serstech
- SATIR
- VacCoat
- Zurich
- Neware
- Pine Research
- OKOndt Group
- Novocontrol
- Norecs
- METERTEST
- Microrad
- Metrel
- Labdex
- SDT
- micrux
- AARONIA AG
- ADASH
- Amptek
- AOiP
- AstroNova
- AWSensors
- Automatic Research
- BASI
- BRS
- Cmc
- CTRL
- CALMET
- CHECKLINE
- C-Tech
- DV Power
- DANATRONICS
- ECH
- Elsys
- Enervac
- Enapter
- ELVEFLOW
- EA Technology
- EL-CELL
- ENERGY SUPPORT
- Electrothermal
- FASTEC
- GE
- GMW
- Gaskatel
- GIUSSANI
- Globecore
- GREENLIGHT
- GRZ
- HTW
- HIGH SENSE SOLUTIONSHTW
- HUBER
- Labnics
- Ida
- LIQUID
- Instytut Fotonowy
- KEHUA TECH
- JGG
- HVPD
- Jenway
- Jacomex
- IVIUM
- ndb
- OZM
- Redoxme
- Serstech
- SATIR
- VacCoat
- Zurich
Flash 四通道火焰光度計
Flash Flame Photometer 型號:Flash-
BWB Flash 最新推出的火焰光度計,是第一個也是唯一一個完全可配置的、最多四通道的火焰光度計,可同時偵測並顯示所有校準離子。BWB Flash 的啟發是基於我們屢獲殊榮的 XP 型號與創新的尖端技術相結合,提供無與倫比的準確性、可用性和可靠性,同時顯著縮短分析時間,並將以往的鍵盤與LCD螢幕升級為5吋彩色電容觸控螢幕,讓使用者的操作體驗更加流暢。當需要不同的測量時,我們的客戶不再需要浪費寶貴的時間更換過濾器和重新校準,而這是從 1951 年至今所有其他火焰光度計設計的常見要求。
它的金屬外殼提供可攜式儀器必須的堅固外,並為未來的回收利用提供了機會。盡可能使用符合 ROHS 標準的組件和材料。
BWB 碳足跡極低,始終堅持著成為負責任製造商的企業為目標,與先前推出的幾代型號相比,我們成功地將天然氣消耗率降低了 13%,同時將電力消耗 (kWh) 降低了 26%。
與其它對重要配件收取額外費用的製造商不同,BWB 包含開箱即用的產品所需的一切。只需加氣體!!(如 : 丙烷、液化石油氣或丁烷)。
我們還提供通過USB從BWB Flash的數據共享到您的PC。這將BWB火焰發射光譜儀(FES)的輸出連接到網際網路或您的公司內部網系統,並促進分佈式控制,這對跨國公司、大學和各種政府機構至關重要。
BWB Flash系列共提供 7 種不同的型號做選擇,皆具有各種不同的偵測功能。下表詳細介紹了各個型號所對應的檢測元素:
型號 檢測元素 FL-C CA FL-K K FL-L Li FL-N Na FL-2 Na、K FL-3 Na、K、Li FL-4 Na、K、Li、Ca
產品特點:- 大型 5 吋觸控螢幕,可與大多數一次性實驗室手套相容。
- 大按鈕和易於理解的文字和符號,真正易於使用。
- 內建空氣壓縮機和氣體調節器。
- 提供校準標準品,濃度為 10,000ppm。
- 自動讀取技術使操作員能夠獨立確定結果。
- 使用者可選擇小數位。
- 提供 IQ、OQ、PQ 基於網路的認證:IQ OQ PQ 是分析儀器領域完全獨特的。有英語、俄語、德語、普通話、法語和西班牙語版本。更多語言正在開發中。
- 含括基本儀器所需器具,可協助您入門。
-
Sample rate
2.5 – 4ml/min
Tubing materials
Silicone and Tygon®
Required desk space for Instrument
101*cm (H) x 45cm (W) x 35cm (D)
*For Safety reasons the Flame photometer
requires 1m of unobstructed space
above to allow dissipation of
heat from the chimney.Instrument size
Flash Photometer
51cm (H) x 33cm (W) x 35cm (D)
(20in x 13in x 14in)Shipping
65cm (H) x 49cm (W) x 43cm (D)
(25in x 19in x 17in)Weight
Flash Photometer – 10kg (22.1lbs)
Shipping – 18kg (39.7 lbs)*
*subject to vary based on accessories included
Power requirements
100V – 250V AC at 50 or 60Hz automatically selecting
Readout
5" colour capacitive touch screen display
Optimal range
Single point calibration
Na 0.1 – 60ppm
K 0.05 – 100ppm
Li 0.05 – 50ppm
Ca 1.0 – 100ppm
Multi Point Calibration (with dilution)
Na 0.1 – 1000ppm
K 0.05 – 1000ppm
Li 0.05 – 1000ppm
Ca 1.0 – 1000ppm
Reproducibility
<1% Coefficient of variability for 20 consecutive
samples over ten minutes at
concentrations of 100ppm or less.
(After instrument stabilisation).Specificity
Na/K/Li = <1% to each other when
equal in concentration at <100ppmLimit of detection (LOD) and
limit of quantification (LOQ)LOD LOQ
Na – 0.03ppm Na – 0.1ppm
K – 0.02ppm K – 0.05ppm
Li – 0.02ppm Li – 0.05ppm
Ca – 0.3ppm Ca – 1ppm
Time to stability
Less than 15 seconds after sample is introduced
into the flame.Ions measured
Simultaneous measurement of model specific
elementsInterfaces
USB
0-2.5 volt output (based on sample concentration
linked to element of users choice)Optional 4-20mA output in place of the above
Optional integrated printer
.csv and .pdf generated reports and files via FP-PC
softwareRecommended minimum warm up time based
on ambient temperature21ºC – 25 minutes
Fuel requirement
Propane, Butane or Natural Gas
* regulated to 19Bar.Flow rate of 0.4l/min
*with modifications. BWB Technologies recommends
either Propane or Butane for optimum results. -
- Large 5" touch screen display compatible with the majority of disposable laboratory gloves
- True ease of use with large buttons and simple to understand text and symbols
- Built-in air compressor and gas regulator
- Calibration standards supplied as standard in 10,000ppm concentrations
- Auto-read technology enables operator independent determination of results
- User selectable decimal places
- IQ, OQ, PQ web-based certification available: IQ OQ PQ is completely unique to the analytical instrumentation arena. Available in English, Russian, German, Mandarin, French and Spanish. More languages in development.
- Complete set of basic labware included to get you started
-
Sample rate
2.5 – 4ml/min
Tubing materials
Silicone and Tygon®
Required desk space for Instrument
101*cm (H) x 45cm (W) x 35cm (D)
*For Safety reasons the Flame photometer
requires 1m of unobstructed space
above to allow dissipation of
heat from the chimney.Instrument size
Flash Photometer
51cm (H) x 33cm (W) x 35cm (D)
(20in x 13in x 14in)Shipping
65cm (H) x 49cm (W) x 43cm (D)
(25in x 19in x 17in)Weight
Flash Photometer – 10kg (22.1lbs)
Shipping – 18kg (39.7 lbs)*
*subject to vary based on accessories included
Power requirements
100V – 250V AC at 50 or 60Hz automatically selecting
Readout
5" colour capacitive touch screen display
Optimal range
Single point calibration
Na 0.1 – 60ppm
K 0.05 – 100ppm
Li 0.05 – 50ppm
Ca 1.0 – 100ppm
Multi Point Calibration (with dilution)
Na 0.1 – 1000ppm
K 0.05 – 1000ppm
Li 0.05 – 1000ppm
Ca 1.0 – 1000ppm
Reproducibility
<1% Coefficient of variability for 20 consecutive
samples over ten minutes at
concentrations of 100ppm or less.
(After instrument stabilisation).Specificity
Na/K/Li = <1% to each other when
equal in concentration at <100ppmLimit of detection (LOD) and
limit of quantification (LOQ)LOD LOQ
Na – 0.03ppm Na – 0.1ppm
K – 0.02ppm K – 0.05ppm
Li – 0.02ppm Li – 0.05ppm
Ca – 0.3ppm Ca – 1ppm
Time to stability
Less than 15 seconds after sample is introduced
into the flame.Ions measured
Simultaneous measurement of model specific
elementsInterfaces
USB
0-2.5 volt output (based on sample concentration
linked to element of users choice)Optional 4-20mA output in place of the above
Optional integrated printer
.csv and .pdf generated reports and files via FP-PC
softwareRecommended minimum warm up time based
on ambient temperature21ºC – 25 minutes
Fuel requirement
Propane, Butane or Natural Gas
* regulated to 19Bar.Flow rate of 0.4l/min
*with modifications. BWB Technologies recommends
either Propane or Butane for optimum results.