AARONIA AG
-
ADASH
-
Amptek
-
AOiP
-
AstroNova
-
Automatic Research
-
AWSensors
-
BASI
-
BRS
-
CALMET
-
CHECKLINE
-
Cmc
-
CTRL
-
DANATRONICS
-
DV Power
-
EA Technology
-
ECH
-
EL-CELL
-
Electrothermal
-
Elsys
-
ELVEFLOW
-
Enapter
-
ENERGY SUPPORT
-
Enervac
-
FASTEC
-
Gaskatel
-
GE
-
GIUSSANI
-
Globecore
-
GMW
-
GREENLIGHT
-
GRZ
-
HIGH SENSE SOLUTIONSHTW
-
HTW
-
HUBER
-
HVPD
-
Ida
-
Instytut Fotonowy
-
IVIUM
-
Jacomex
-
Jenway
-
JGG
-
KEHUA TECH
-
Labdex
-
Labnics
-
LIQUID
-
METERTEST
-
Metrel
-
Microrad
-
micrux
-
ndb
-
Neware
-
Norecs
-
Novocontrol
-
OKOndt Group
-
OZM
-
Pine Research
-
Redoxme
-
SATIR
-
SDT
-
Serstech
-
VacCoat
-
Zurich
- AARONIA AG
- ADASH
- Amptek
- AOiP
- AstroNova
- Automatic Research
- AWSensors
- BASI
- BRS
- CALMET
- CHECKLINE
- Cmc
- CTRL
- DANATRONICS
- DV Power
- EA Technology
- ECH
- EL-CELL
- Electrothermal
- Elsys
- ELVEFLOW
- Enapter
- ENERGY SUPPORT
- Enervac
- FASTEC
- Gaskatel
- GE
- GIUSSANI
- Globecore
- GMW
- GREENLIGHT
- GRZ
- HIGH SENSE SOLUTIONSHTW
- HTW
- HUBER
- HVPD
- Ida
- Instytut Fotonowy
- IVIUM
- Jacomex
- Jenway
- JGG
- KEHUA TECH
- Labdex
- Labnics
- LIQUID
- METERTEST
- Metrel
- Microrad
- micrux
- ndb
- Neware
- Norecs
- Novocontrol
- OKOndt Group
- OZM
- Pine Research
- Redoxme
- SATIR
- SDT
- Serstech
- VacCoat
- Zurich
Calport 100 或 Calport 100 Plus 測試軟體
PC Software for a Calport 100 or Calport 100 Plus tester 型號:Calsoft 100-
- reading actual measured values from the Calport 100 using RS232C interface and their visualisation on PC screen. The readings can be done automatically by user defined period of time,
- reading data, earlier stored in analyser’s memory (up to 40 sets of data) and their visualisation on PC screen,
- visualisation of three phase vector chart,
- export of measured data to Microsoft Excel, which enables later their processing according to the user’s requirements.
- printing data and charts on the printer, • saving and reading data to and from files for making archives of measurements.
-
Function / parameter
Range
Error 1) 2) 3) 6)
class 0.1
class 0.2
Direct voltage
30…480V
0.05...30V±0.1%
±0.1%*±0.2%
±0.2%*Voltage with VoltLiteWire
0.5…40kV
±0.1%±Em ±0.2%±Em
Direct current
0.04…12A
0.001…0.04A±0.1%
±0.1%*±0.2%
±0.2%*Current with clamps 10A
0.1…10A
0.005…0.1A±0.5%
±0.5%*±0.5%
±0.5%*Current
with clamps 100A0.5…100A
0.01…0.5A±0.2%
±0.2%*±0.2%
±0.2%*Current
with clamps 1000A20…1000A
0.1…20A±0.5%
±0.5%*±0.5%
±0.5%*Current
with clamps 3000A60…3000A
0.3…60A±1%
±1%*±1%
±1%*Current with flex
0...30A/300A/3000A
±0.1%±Em ±0.2%±Em
Current
with AmpLiteWire30…2000A
±0.1%±Em ±0.2%±Em
Power and energy direct measure
0.04...12A / 30...480V
0.001........ A / 30…480V±0.1%
±0.1%*±0.2%
±0.2%*Power and energy with clamps 10A
0.1...10A / 30...480V
0.005...... A / 30…480V±0.5%
±0.5%*±0.5%
±0.5%*Power and energy with clamps 100A
0.5...100A / 30...480V
0.01...... A / 30…480V±0.2%
±0.2%*±0.2%
±0.2%*Power and energy with clamps 1000A
20…1000A / 30...480V
0.1...20A / 30…480V±0.5%
±0.5%*±0.5%
±0.5%*Power and energy with clamps 3000A
60…3000A / 30...480V
0.3…60A / 30…480V±1%
±1%*±1%
±1%*Power and energy
with flexible clamps0...30A/300A/3000A /
30...480V±0.1%±Em ±0.2%±Em
Power and energy
with clamps LiteWire30…2000A / 0.5…40kV
±0.1%±Em
±0.2%±Em
Resolution of energy meter error measurement "e"
0.0001%
0.0001%
Phase shift direct connection with clamps
0...±360°
±0.4° 4)
±0.5° 5)±0.4° 4)
±0.5° 5)Power factor
cos j and sin j0.000...±1.000
±0.01
±0.01
Frequency
45...65Hz
±0.05Hz
±0.05Hz
Ambient temperature
-5...+50°C operating, -20...+60°C transportation
Power supply
85..230..265V / DC or 45..65Hz / 10VA
Dimensions and weight of analyser
270 / 240 / 180 mm / 3.5 kg
Dimensions of analyser set
420 / 280 / 370 mm
1) % - related to the measuring value, %* - related to the measuring final value
2) Em-sensor basic error, Em=1%+0,1%* for flexible clamps and Em=2%+0,2%* for LiteWire sensors
3) Power and energy errors related to apparent power
4) In current range 0,04…12A and in voltage range 30…480V
5) From 10% of current range and in voltage range 30…480V
6) Power and energy errors is doubled for input wiring 3 phase 3 wire (Aron measuring system)