0 like search mail home
選擇品牌 arrow_down

CMP-401

Digital Clamp-on multimeter 型號:CMP-401
DC current measurement and AC current.
  • AC/DC voltage measurement up to 600 V.Resistance measurement and continuity test:

    • continuity test with acoustic signalling (beeper) for resistance below 50.
    Temperature measurement (Fahrenheit and Celsius units).
    Frequency measurement.
    Capacitance measurement .
    Diode test.


    Additionally:
    • safe, insulated measuring clamps,
    • double molded housing,
    • autoranging/manual range selection,
    • DATA HOLD function, for holding measured values,
    • backlit LCD,
    • REL function,
    • over range indication,

    AUTO-OFF function.

  • DC current measurement and AC current. .
    AC/DC voltage measurement up to 600 V.

    Resistance measurement and continuity test:

    • continuity test with acoustic signalling (beeper) for resistance below 50 Ω.

    Temperature measurement (Fahrenheit and Celsius units).
    Frequency measurement.
    Capacitance measurement
    Diode test.
    Additionally:

    • safe, insulated measuring clamps,
    • double molded housing,
    • autoranging/manual range selection,
    • „DATA HOLD” function, for holding measured values,
    • backlit LCD,
    • „REL” function,
    • over range indication,
    • „AUTO-OFF” function.

    Electric security:

    • measurement category: CAT III 600 V acc. to EN 61010 - 1:2004
    • protection class acc. to EN 60529: IP40

    Other technical data:

    • power supply: 9 V battery type 6LR61
    • display: 4000 counts, backlit LCD
    • continuity test: I<0,5 mA, sound signal for R<50 Ω
    • diode test: I = 0,3 mA, U0 = 1,5 V DC
    • over range indication: 0L displayed
    • sampling rate: 2 times per second
    • input impedance: 10 MΩ (V DC and V AC)
    • clamp size: opening 30 mm (1,2”)
    • auto power OFF: approx. 30 min.
    • dimensions: 197 x 70 x 40 mm
    • weight: 183 g
    • accordance with following standards: EN 61010 - 1:2004, EN 61010 - 2 - 032
    • quality standard: ISO 9001

    Rated operational conditions:

    • operating temperature: 0...+40°C
    • storage temperature: -20...+60°C
    • operating humidity: max 80% up to 31°C; decreasing linearly to 50% at 40°C
    • operating altitude: max 2000 m

    Temperature measurement

    Range Accuracy
    -20,0...760°C ±(3% m.v. + 5°C)
    -4,0...1400°F ±(3% m.v. + 9°F)

    *probe (K type) accuracy not included

     Frequency measurement

    Range Accuracy
    10 Hz ... 10 kHz ±(1,5% m.v. + 2 digits)
    • csensitivity: 100 V (<50 Hz), 50 V (50…400 Hz); 15 V (401 Hz…10 kHz)

     AC current measurement

    Range Resolution Accuracy
    40,00 A 0,01 A ±(2,5% m.v. + 8 digits)
    400,0 A 0,1 A ±(2,8% m.v. + 5 digits)
    • frequency range: 50...60 Hz.

    DC current measurement

    Range Resolution Accuracy
    40,00 A 0,01 A ±(2,5% m.v. + 5 digits)
    400,0 A 0,1 A ±(2,8% m.v. + 5 digits)

     AC voltage measurement

    Range Resolution Accuracy
    400,0 mV 0,1 mV ±(1,5% m.v. + 30 digits)
    4,000 V 0,001 V ±(1,5% m.v. + 5 digits)
    40,00 V 0,01 V ±(1,5% m.v. + 5 digits)
    400,0 V 0,1 V ±(1,5% m.v. + 5 digits)
    600,0 V 1 V ±(2% m.v. + 5 digits)
    • frequency range: 50...400 Hz.

     DC voltage measurement

    Range Resolution Accuracy
    400,0 mV 0,1 mV ±(0,8% m.v. + 2 digits)
    4,000 V 0,001 V ±(1,5% m.v. + 2 digits)
    40,00 V 0,01 V ±(1,5% m.v. + 2 digits)
    400,0 V 0,1 V ±(1,5% m.v. + 2 digits)
    600,0 V 1 V ±(2% m.v. + 2 digits)

     Resistance measurement

    Range Resolution Accuracy
    400,0 Ω 0,1 Ω ±(1,0% m.v. + 4 digits)
    4,000 kΩ 0,001 kΩ ±(1,5% m.v. + 2 digits)
    40,00 kΩ 0,01 kΩ ±(1,5% m.v. + 2 digits)
    400,0 kΩ 0,1 kΩ ±(1,5% m.v. + 2 digits)
    4,000 MΩ 0,001 MΩ ±(2,5% m.v. + 3 digits)
    40,00 MΩ 0,01 MΩ ±(3,5% m.v. + 5 digits)

     Capacitance measurement

    Range Resolution Accuracy
    40,00 nF 0,01 nF ±(4% m.v. + 20 digits)
    400,0 nF 0,1 nF ±(3% m.v. + 5 digits)
    4,000 nF 0,001 μF ±(3% m.v. + 5 digits)
    40,00 nF 0,01 μF ±(3% m.v. + 5 digits)
    100,0 nF 0,1 μF ±(4% m.v. + 10 digits)

    „m.v.”- measured value