選擇品牌
- Neware
- Pine Research
- OKOndt Group
- Novocontrol
- Norecs
- METERTEST
- Microrad
- Metrel
- Labdex
- SDT
- micrux
- AARONIA AG
- ADASH
- Amptek
- AOiP
- AstroNova
- AWSensors
- Automatic Research
- BASI
- BRS
- BWB Technologies
- Cmc
- CTRL
- CALMET
- CHECKLINE
- Coxem
- C-Tech
- DV Power
- DANATRONICS
- ECH
- Elsys
- Enervac
- Enapter
- ELVEFLOW
- EA Technology
- EL-CELL
- ENERGY SUPPORT
- Electrothermal
- FASTEC
- GE
- GMW
- Gaskatel
- GIUSSANI
- Globecore
- GREENLIGHT
- GRZ
- HTW
- HIGH SENSE SOLUTIONSHTW
- HUBER
- Labnics
- Ida
- LIQUID
- Instytut Fotonowy
- KEHUA TECH
- JGG
- HVPD
- Jenway
- Jacomex
- IVIUM
- ndb
- OZM
- Redoxme
- Serstech
- SATIR
- VacCoat
- Zurich
- Neware
- Pine Research
- OKOndt Group
- Novocontrol
- Norecs
- METERTEST
- Microrad
- Metrel
- Labdex
- SDT
- micrux
- AARONIA AG
- ADASH
- Amptek
- AOiP
- AstroNova
- AWSensors
- Automatic Research
- BASI
- BRS
- BWB Technologies
- Cmc
- CTRL
- CALMET
- CHECKLINE
- Coxem
- C-Tech
- DV Power
- DANATRONICS
- ECH
- Elsys
- Enervac
- Enapter
- ELVEFLOW
- EA Technology
- EL-CELL
- ENERGY SUPPORT
- Electrothermal
- FASTEC
- GE
- GMW
- Gaskatel
- GIUSSANI
- Globecore
- GREENLIGHT
- GRZ
- HTW
- HIGH SENSE SOLUTIONSHTW
- HUBER
- Labnics
- Ida
- LIQUID
- Instytut Fotonowy
- KEHUA TECH
- JGG
- HVPD
- Jenway
- Jacomex
- IVIUM
- ndb
- OZM
- Redoxme
- Serstech
- SATIR
- VacCoat
- Zurich
CRYOSTATIC BATH
CRYOSTATIC BATH 型號:BK40 M-TR- Temperature range: -40 °C ÷ 125 °C
- Stability: ±0,01 °C
-
- Accuracy: ±0,20 @ 120 °C
- Well depth: 330 mm
- Working diameter: 75 mm
-
Product name BK40 M BK40 M‐TR (5) TB300 M TB300 M‐TR (5) Temp. range (°C) ‐40 (*) ÷ 125 (2) ‐40 (*) ÷ 125 (2) 50 ÷ 260 (3)(4) 50 ÷ 260 (3)(4) Type Liquid Liquid Liquid Liquid Stability (°C) ±0,05 (1) ±0,01 (2) ±0,05 (3) ±0,01 (3) Uniformity Radial (°C)
Axial (°C)@ 60 °C (1)
±0,02 (@ 100 mm)
±0,02 (@ 120 mm)@ 80 °C (2)
±0,01 (@ 100 mm)
±0,01 (@ 120 mm)@ 120 °C (3)
±0,02 (@ 100 mm)
±0,02 (@ 120 mm)@ 200 °C (3)
±0,005 (@ 100 mm)
±0,005 (@ 120 mm)Stability indicator Audio + visual Audio + visual Audio + visual Audio + visual Display accuracy (°C) ±0,20 ±0,20 ±0,20 ±0,20 Display resolution (°C) 0,1 / 0,01 0,1 / 0,01 0,1 / 0,01 0,1 / 0,01 Ext. probe reading Optional Optional Optional Optional Units of measurement °C / °F / K °C / °F / K °C / °F / K °C / °F / K Interface RS232 RS232 RS232 RS232 Mean heating time 2 °C/min (1) 2 °C/min (1) 6 °C/min (3) 6 °C/min (3) Mean cooling time 0,5 °C/min (1) 0,5 °C/min (1) — — Slope ● ● ● ● Switch test ● ● ● ● Well depth (mm) 340 330 340 330 Working diameter (mm) 105 75 123 75 Size (mm) 450 x 450 x 1270 450 x 450 x 1270 450 x 450 x 1270 450 x 450 x 1270 Weight (kg) 70 73 44 47 Power supply (V) ‐ (50/60 Hz) 230 230 230 230 Power (W) 2500 2500 1600 1600 * Ambient temperature: 20 °C
- With ethylene glycol
- With silicon oil 200C5
- With silicon oil 47V100
- Maximum range Amb. ÷ 300 °C