- Neware
- Pine Research
- OKOndt Group
- Novocontrol
- Norecs
- METERTEST
- Microrad
- Metrel
- Labdex
- SDT
- micrux
- AARONIA AG
- ADASH
- Amptek
- AOiP
- AstroNova
- AWSensors
- Automatic Research
- BASI
- BRS
- Cmc
- CTRL
- CALMET
- CHECKLINE
- C-Tech
- DV Power
- DANATRONICS
- ECH
- Elsys
- Enervac
- Enapter
- ELVEFLOW
- EA Technology
- EL-CELL
- ENERGY SUPPORT
- Electrothermal
- FASTEC
- GE
- GMW
- Gaskatel
- GIUSSANI
- Globecore
- GREENLIGHT
- GRZ
- HTW
- HIGH SENSE SOLUTIONSHTW
- HUBER
- Labnics
- Ida
- LIQUID
- Instytut Fotonowy
- KEHUA TECH
- JGG
- HVPD
- Jenway
- Jacomex
- IVIUM
- ndb
- OZM
- Redoxme
- Serstech
- SATIR
- VacCoat
- Zurich
- Neware
- Pine Research
- OKOndt Group
- Novocontrol
- Norecs
- METERTEST
- Microrad
- Metrel
- Labdex
- SDT
- micrux
- AARONIA AG
- ADASH
- Amptek
- AOiP
- AstroNova
- AWSensors
- Automatic Research
- BASI
- BRS
- Cmc
- CTRL
- CALMET
- CHECKLINE
- C-Tech
- DV Power
- DANATRONICS
- ECH
- Elsys
- Enervac
- Enapter
- ELVEFLOW
- EA Technology
- EL-CELL
- ENERGY SUPPORT
- Electrothermal
- FASTEC
- GE
- GMW
- Gaskatel
- GIUSSANI
- Globecore
- GREENLIGHT
- GRZ
- HTW
- HIGH SENSE SOLUTIONSHTW
- HUBER
- Labnics
- Ida
- LIQUID
- Instytut Fotonowy
- KEHUA TECH
- JGG
- HVPD
- Jenway
- Jacomex
- IVIUM
- ndb
- OZM
- Redoxme
- Serstech
- SATIR
- VacCoat
- Zurich
BIO 火焰光度計
BIO Flame Photometer 型號:BIO-
BWB BIO 專為測量生物應用領域而打造,並針對當今的研究工作進行了現代化改造並具有分析血液噢尿液的特殊內置;這需要對Li、Ca、Na和K元素進行常規、快速且高精確度的測量。
我們最近發布的內容是德國、智利、哥倫比亞、美國和加拿大博士的幾個「願望清單」的組合,主要從事腎臟研究、糖尿病和阿茲海默症研究。我們對所有原子獨特的同步檢測和數據處理,不僅可以快速促進生產試劑和解決方案,並且同時兼顧品質的保證和控管。
當使用 BWB FP-PC 應用程式連接到 PC 時,使用者可以建立 .pdf 檔案、.csv 檔案、資料展示和包含所有關鍵分析資料的報告。FP-PC 軟體使您能夠檢視與編輯校準曲線,還允許設定自動流體處理系統( AFHS),該系統最初設計為專門與 BIO 裝置配合使用。
對於特定嚴格的測試實驗室中不允許使用 PC 或資料擷取的限制,配置的印表機提供您紙本的數據取得途徑。印表機採用環保列印墨水,字元捕捉壽命最低為10年。該印表機也與其他現成的紙材相容。
無疑的BWB BIO 是當今研究實驗室的必備儀器,其直觀且友好的使用者操作介面突破語言的隔閡,對各個層級的使用者都具有吸引力。
為了提高準確性和再現性,可以選擇使用銫或鋰作為內參比系統 (IRS),作為內標來調整校準和測量過程中的微小變化。
產品特點:
- 針對使用者分析元素作專門配置。
- 「IRS」(內部參考標準)銫或鋰選項。
- 單點校準校正。
- 內部參考標準。
- 提供尿液和血清專用的 5 點和 6 點多離子校準標準品。
- 分析 Li 和 Ca 以及 Na 和 K。
- 操作員獨立確定結果。
- 先進的自動確定結果。
- 採用環保墨水的一體式印表機。
- BIO 上的 IQ、OQ、PQ 基於網路的認證標準,可在所有 BWB FES 裝置上使用。
- 校正 Ca 以消除高濃度 Na 的干擾。
-
Sample rate
2 – 3.5ml/min
Tubing materials
Silicone and Tygon®
Specificity
Na/K/Li = <1% to each other when
equal in concentration at <100ppmRequired desk space for Instrument
50cm (H) x 45cm (W) x 45cm (D)
For Safety reasons the Flame photometer requires1m of
unobstructed space above to allow
dissipation of heat from the chimney.Instrument size
BIO Flame Photometer
51cm (H) x 39cm (W) x 35cm (D)
(20in x 15in x 14in)Shipping
65cm (H) x 49cm (W) x 43cm (D)
(25in x 19in x 17in)Weight
BIO Flame Photometer 14kg (30.8lbs)
Shipping 25kg (55.1lbs)
Power requirements
100V – 250V AC at 50 or 60Hz
Readout
LCD, four line, alpha numeric, back lit.
Optimal range
Multi-point calibration
Na – 0.0043 – 300mmol/l*
K – 0.0013 – 200mmol/*
Li – 0.0072 – 20mmol/l*
Ca – 0.025 – 20mmol/l*
*With required Dilution Ratios
Reproducibility
<1% Coefficient of variability for 20
consecutive samples over ten minutes
at concentrations of 100ppm
equivalent or less. (After instrument
stabilisation).Limit of detection (LOD) and limit of quantification (LOQ)
LOD LOQ
Na – 0.0013mmol/l Na – 0.0043mmol/l
K – 0.0005mmol/l K – 0.0013mmol/l
Li – 0.003mmol/l Li – 0.0072mmol/l
Ca – 0.0075mmol/l Ca – 0.025mmol/l
Time to stability
Less than 15 seconds after sample is introduced into the flame
Ions measured
Serum Na and K or Li and Ca
Urine Na and K or Li and CaRecommended minimum warm up time based on ambient temperature
21°C – 25 minutes
Calibration concentrations
URINE
Point 1 Point 2 Point 3
Na 25mmol/l Na 50mmol/l Na 100mmol/l
K 25mmol/l K 50mmol/l K 100mmol/l
Li 2.5mmol/l Li 5mmol/l Li 10mmol/l
Ca 2.5mmol/l Ca 5mmol/l Ca 10mmol/lPoint 4 Point 5
Na 200mmol/l Na 300mmol/l
K 150mmol/l K 200mmol/l
Li 15mmol/l Li 20mmol/l
Ca 15mmol/l Ca 20mmol/l
SERUM
Point 1 Point 2 Point 3
Na 120mmol/l Na 130mmol/l Na 140mmol/l
K 3mmol/l K 4mmol/l K 5mmol/l
Li 0.25mmol/l Li 0.5mmol/l Li 1mmol/l
Ca 1.5mmol/l Ca 2mmol/l Ca 2.5mmol/lPoint 4 Point 5
Na 150mmol/l Na 160mmol/l
K 6mmol/l K 7mmol/l
Li 1.5mmol/l Li 2mmol/l
Ca 3mmol/l Ca 3.5mmol/l
Fuel requirement
Propane, Butane or Natural Gas*
regulated to 19Bar. Flow rate of 0.4l/min*with modifications. BWB Technologies recommends
either Propane or Butane for optimum results. -
- Specially configured for a range of user interests
- “IRS” (Internal Reference Standard) caesium or lithium option
- Single point calibration correction
- Internal reference standards
- 5 and 6 point multi-ion calibration standards for urine and serum included
- Analysing Li and Ca along with Na and K
- Operator independent determination of results
- Advanced automated determination of results
- Integrated printer with environmentally friendly ink
- IQ, OQ, PQ web-based certification standard on BIO and available on all BWB FES units
- Correction of Ca for the interference from high levels of Na
-
Sample rate
2 – 3.5ml/min
Tubing materials
Silicone and Tygon®
Specificity
Na/K/Li = <1% to each other when
equal in concentration at <100ppmRequired desk space for Instrument
50cm (H) x 45cm (W) x 45cm (D)
For Safety reasons the Flame photometer requires1m of
unobstructed space above to allow
dissipation of heat from the chimney.Instrument size
BIO Flame Photometer
51cm (H) x 39cm (W) x 35cm (D)
(20in x 15in x 14in)Shipping
65cm (H) x 49cm (W) x 43cm (D)
(25in x 19in x 17in)Weight
BIO Flame Photometer 14kg (30.8lbs)
Shipping 25kg (55.1lbs)
Power requirements
100V – 250V AC at 50 or 60Hz
Readout
LCD, four line, alpha numeric, back lit.
Optimal range
Multi-point calibration
Na – 0.0043 – 300mmol/l*
K – 0.0013 – 200mmol/*
Li – 0.0072 – 20mmol/l*
Ca – 0.025 – 20mmol/l*
*With required Dilution Ratios
Reproducibility
<1% Coefficient of variability for 20
consecutive samples over ten minutes
at concentrations of 100ppm
equivalent or less. (After instrument
stabilisation).Limit of detection (LOD) and limit of quantification (LOQ)
LOD LOQ
Na – 0.0013mmol/l Na – 0.0043mmol/l
K – 0.0005mmol/l K – 0.0013mmol/l
Li – 0.003mmol/l Li – 0.0072mmol/l
Ca – 0.0075mmol/l Ca – 0.025mmol/l
Time to stability
Less than 15 seconds after sample is introduced into the flame
Ions measured
Serum Na and K or Li and Ca
Urine Na and K or Li and CaRecommended minimum warm up time based on ambient temperature
21°C – 25 minutes
Calibration concentrations
URINE
Point 1 Point 2 Point 3
Na 25mmol/l Na 50mmol/l Na 100mmol/l
K 25mmol/l K 50mmol/l K 100mmol/l
Li 2.5mmol/l Li 5mmol/l Li 10mmol/l
Ca 2.5mmol/l Ca 5mmol/l Ca 10mmol/lPoint 4 Point 5
Na 200mmol/l Na 300mmol/l
K 150mmol/l K 200mmol/l
Li 15mmol/l Li 20mmol/l
Ca 15mmol/l Ca 20mmol/l
SERUM
Point 1 Point 2 Point 3
Na 120mmol/l Na 130mmol/l Na 140mmol/l
K 3mmol/l K 4mmol/l K 5mmol/l
Li 0.25mmol/l Li 0.5mmol/l Li 1mmol/l
Ca 1.5mmol/l Ca 2mmol/l Ca 2.5mmol/lPoint 4 Point 5
Na 150mmol/l Na 160mmol/l
K 6mmol/l K 7mmol/l
Li 1.5mmol/l Li 2mmol/l
Ca 3mmol/l Ca 3.5mmol/l
Fuel requirement
Propane, Butane or Natural Gas*
regulated to 19Bar. Flow rate of 0.4l/min*with modifications. BWB Technologies recommends