選擇品牌

-
Neware
-
Pine Research
-
OKOndt Group
-
Novocontrol
-
Norecs
-
METERTEST
-
Microrad
-
Metrel
-
Labdex
-
SDT
-
micrux
-
AARONIA AG
-
ADASH
-
Amptek
-
AOiP
-
AstroNova
-
AWSensors
-
Automatic Research
-
BASI
-
BRS
-
Cmc
-
CTRL
-
CALMET
-
CHECKLINE
-
C-Tech
-
DV Power
-
DANATRONICS
-
ECH
-
Elsys
-
Enervac
-
Enapter
-
ELVEFLOW
-
EA Technology
-
EL-CELL
-
ENERGY SUPPORT
-
Electrothermal
-
FASTEC
-
GE
-
GMW
-
Gaskatel
-
GIUSSANI
-
Globecore
-
GREENLIGHT
-
GRZ
-
HTW
-
HIGH SENSE SOLUTIONSHTW
-
HUBER
-
Labnics
-
Ida
-
LIQUID
-
Instytut Fotonowy
-
KEHUA TECH
-
JGG
-
HVPD
-
Jenway
-
Jacomex
-
IVIUM
-
ndb
-
OZM
-
Redoxme
-
Serstech
-
SATIR
-
VacCoat
-
Zurich
- Neware
- Pine Research
- OKOndt Group
- Novocontrol
- Norecs
- METERTEST
- Microrad
- Metrel
- Labdex
- SDT
- micrux
- AARONIA AG
- ADASH
- Amptek
- AOiP
- AstroNova
- AWSensors
- Automatic Research
- BASI
- BRS
- Cmc
- CTRL
- CALMET
- CHECKLINE
- C-Tech
- DV Power
- DANATRONICS
- ECH
- Elsys
- Enervac
- Enapter
- ELVEFLOW
- EA Technology
- EL-CELL
- ENERGY SUPPORT
- Electrothermal
- FASTEC
- GE
- GMW
- Gaskatel
- GIUSSANI
- Globecore
- GREENLIGHT
- GRZ
- HTW
- HIGH SENSE SOLUTIONSHTW
- HUBER
- Labnics
- Ida
- LIQUID
- Instytut Fotonowy
- KEHUA TECH
- JGG
- HVPD
- Jenway
- Jacomex
- IVIUM
- ndb
- OZM
- Redoxme
- Serstech
- SATIR
- VacCoat
- Zurich
-
- Determination of moisture in liquefied and gaseous samples
- Inlet pressure up to 200 bar/2900 psi
- Determination of pressure in the sample loop
- Automatic pressure regulation
- Transfer line with direct injection
- Automatic rinsing bypass and steps for rinsing
- Measuring cell without diaphragm (only one electrolyte required)
- Setting of application-specific methods
- Sulphur trap eliminating the side reactions caused by sulphides/H2S
- Type of result: µg, ppm (gas volume), Vppm, Mppm, Mol ppm by using the formula generator
Areas of Application
LPG, LNG
- propane, propene, butane, butene, butadiene
- ethylene oxide
- chlorinated hydrocarbons, e. g. methylene chloride, ethylene chloride, vinyl chloride
Analysis of refrigerants:
- halogenated hydrocarbons
Analysis of permanent gases:
- natural gas
- technical gases
- mixtures of test gases
Advantages
- Sulphur removal cartridge eliminating the side reactions caused by sulphides/H2S
- No interference calculation required
- 250 measurements can be performed in 48 hours
- Totally automated process, no operator input required for the test
- Suitable to test all gas types without any calibration or adjustments
- No separate rinsing gas is required
- Rinsing process is fully automated
- No balance is required
- High sample throughput and long reagent life
- Compact device
-
Measurement method: Coulometric Karl Fischer titration Sample: Pressurized gas sample (LNG, LPG) Sample dosing: Pressurized bottle or
directly from the gas linePressure reducer: internal (with heating element) Sample loop: 300 mL (gas) Rinsing and dosing: 0 … 15 steps for each, adjustable Measuring range: 1 μg ... 100 % Resolution: 0.1 ppm Detection limit: 1 ppm Power supply: 230 V/50 Hz; 115 V/60 Hz Dimensions: 33 x 49 x 48 cm (W x D x H) Weight: 24.0 kg Device control: PC software
(PC not included in the scope of delivery)