選擇品牌
- Neware
- Pine Research
- OKOndt Group
- Novocontrol
- Norecs
- METERTEST
- Microrad
- Metrel
- Labdex
- SDT
- micrux
- AARONIA AG
- ADASH
- Amptek
- AOiP
- AstroNova
- AWSensors
- Automatic Research
- BASI
- BRS
- BWB Technologies
- Cmc
- CTRL
- CALMET
- CHECKLINE
- Coxem
- C-Tech
- DV Power
- DANATRONICS
- ECH
- Elsys
- Enervac
- Enapter
- ELVEFLOW
- EA Technology
- EL-CELL
- ENERGY SUPPORT
- Electrothermal
- FASTEC
- GE
- GMW
- Gaskatel
- GIUSSANI
- Globecore
- GREENLIGHT
- GRZ
- HTW
- HIGH SENSE SOLUTIONSHTW
- HUBER
- Labnics
- Ida
- LIQUID
- Instytut Fotonowy
- KEHUA TECH
- JGG
- HVPD
- Jenway
- Jacomex
- IVIUM
- ndb
- OZM
- Redoxme
- Serstech
- SATIR
- VacCoat
- Zurich
- Neware
- Pine Research
- OKOndt Group
- Novocontrol
- Norecs
- METERTEST
- Microrad
- Metrel
- Labdex
- SDT
- micrux
- AARONIA AG
- ADASH
- Amptek
- AOiP
- AstroNova
- AWSensors
- Automatic Research
- BASI
- BRS
- BWB Technologies
- Cmc
- CTRL
- CALMET
- CHECKLINE
- Coxem
- C-Tech
- DV Power
- DANATRONICS
- ECH
- Elsys
- Enervac
- Enapter
- ELVEFLOW
- EA Technology
- EL-CELL
- ENERGY SUPPORT
- Electrothermal
- FASTEC
- GE
- GMW
- Gaskatel
- GIUSSANI
- Globecore
- GREENLIGHT
- GRZ
- HTW
- HIGH SENSE SOLUTIONSHTW
- HUBER
- Labnics
- Ida
- LIQUID
- Instytut Fotonowy
- KEHUA TECH
- JGG
- HVPD
- Jenway
- Jacomex
- IVIUM
- ndb
- OZM
- Redoxme
- Serstech
- SATIR
- VacCoat
- Zurich
-
Water extraction of the samples at temperatures 35 °C up to 250 °C, e. g.:
- Constant temperature
- Individually set up temperature programs
- Freely selectable temperature ramp
- Time-controlled temperature programs for step-by-step heating
- Type of result: µg, µg/L, mg/L, mg/kg, ppm, %, by using the formula generator
Areas of Application
- Transformer oils
- Hydraulic oils
- Engine oils
- Gear oils
- Crude oil
- Fuel oil
- Gasoline
- Diesel
- Jet fuel
- Bio fuel
- Petroleum products
- Insulating oils
- Silicone oil
- Lubricating oils
- Biopetroleum
- Biological oils
Advantages
- Closed loop principle does not allow methanol to evaporate from the KF solvent
- Reagent capacity is used completely
- Additive and Sulphur side reactions minimized
- By using of temperature programs it is possible to separate free and chemically bonded water
- Temperature ramping program allows you to distinguish between various types of bonded water
- No blank value meaning true ppm accuracy
- Aquamax KF PRO Oil can be used in the laboratory or used as part of a mobile lab when taking a measurement from the sample point is critical
- Compact and rugged device
-
Measurement method: Coulometric Karl Fischer titration Sample administration: Manually with syringe Sample amount: 0.01 - 20 mL Heating temperature: 35 ... 250 °C, isothermal or with temperature program Blank value: 0 µg Measuring range: 0.0001 ... 100 % Power supply: 230 V/50 Hz; 115 V/60 Hz Dimensions: 33 x 39 x 48 cm (W x D x H) Weight: 17.0 kg