- Neware
- Pine Research
- OKOndt Group
- Novocontrol
- Norecs
- METERTEST
- Microrad
- Metrel
- Labdex
- SDT
- micrux
- AARONIA AG
- ADASH
- Amptek
- AOiP
- AstroNova
- AWSensors
- Automatic Research
- BASI
- BRS
- BWB Technologies
- Cmc
- CTRL
- CALMET
- CHECKLINE
- Coxem
- C-Tech
- DV Power
- DANATRONICS
- ECH
- Elsys
- Enervac
- Enapter
- ELVEFLOW
- EA Technology
- EL-CELL
- ENERGY SUPPORT
- Electrothermal
- FASTEC
- GE
- GMW
- Gaskatel
- GIUSSANI
- Globecore
- GREENLIGHT
- GRZ
- HTW
- HIGH SENSE SOLUTIONSHTW
- HUBER
- Labnics
- Ida
- LIQUID
- Instytut Fotonowy
- KEHUA TECH
- JGG
- HVPD
- Jenway
- Jacomex
- IVIUM
- ndb
- OZM
- Redoxme
- Serstech
- SATIR
- VacCoat
- Zurich
- Neware
- Pine Research
- OKOndt Group
- Novocontrol
- Norecs
- METERTEST
- Microrad
- Metrel
- Labdex
- SDT
- micrux
- AARONIA AG
- ADASH
- Amptek
- AOiP
- AstroNova
- AWSensors
- Automatic Research
- BASI
- BRS
- BWB Technologies
- Cmc
- CTRL
- CALMET
- CHECKLINE
- Coxem
- C-Tech
- DV Power
- DANATRONICS
- ECH
- Elsys
- Enervac
- Enapter
- ELVEFLOW
- EA Technology
- EL-CELL
- ENERGY SUPPORT
- Electrothermal
- FASTEC
- GE
- GMW
- Gaskatel
- GIUSSANI
- Globecore
- GREENLIGHT
- GRZ
- HTW
- HIGH SENSE SOLUTIONSHTW
- HUBER
- Labnics
- Ida
- LIQUID
- Instytut Fotonowy
- KEHUA TECH
- JGG
- HVPD
- Jenway
- Jacomex
- IVIUM
- ndb
- OZM
- Redoxme
- Serstech
- SATIR
- VacCoat
- Zurich
New 6850 可變帶寬雙光束分光光譜儀
New 6850 double beam spectrophotometer with variable bandwidth 型號:6850 double beam- Double beam spectrophotometer with highly stable optics
- Variable spectral bandwidth 0.5, 1, 2, 4, 5nm
- Integrated user interface
- USB port for data storage
- Conforms to European Pharmacopeia requirements
- Jenway Prism PC software included as standard
- Extensive range of accessories available
-
- Double beam spectrophotometer with highly stable optics
- Variable spectral bandwidth 0.5, 1, 2, 4, 5nm
- Integrated user interface
- USB port for data storage
- Conforms to European Pharmacopeia requirements
- Jenway Prism PC software included as standard
- Extensive range of accessories available
he new 6850 introduces the first double beam spectrophotometer with a variable spectral bandwidth into the Jenway range. The highly stable optics and two detectors measure the sample and reference simultaneously optimising measurement accuracy. The 6850 has measurement modes for photometrics, concentration, multi-wavelength, spectrum scanning, kinetics, quantitation, DNA/RNA and protein analysis.
Jenway Prism PC software is supplied as standard and offers additional functionality with preloaded methods for DNA/RNA and protein analysis, as well as extensive post-measurement tools, unlimited results saving and easy export of data.
The 6850 double beam spectrophotometer is ideal for quality control, general research, pharmaceutical, biochemical and clinical laboratory applications. -
Parameter 6850 Wavelength range 190 to 1100nm Wavelength resolution 0.1nm Wavelength accuracy ± 0.3nm (at 0.5 and 1nm bandwidth) ± 0.5nm (at 2, 4 and 5nm bandwidth) Wavelength reproducibility ± 0.2nm Spectral bandwidth Variable 0.5, 1, 2, 4, 5nm Photometric range - 0.3 to 3.0A 0 to 200T Photometric accuracy ± 0.002A (0- 0.5A) ± 0.3 T (0- 100T) Photometric reproducibility ± 0.001 Abs (0 to 0.5 Abs) ± 0.002 Abs (0.5 to 1.0 Abs) 0.15T (0- 100T) Resolution 0.1T, 0.001A Stray light 0.05T at 220 and 360nm Noise 0.0005A Stability ± 0.001Ah at 500nm after 15 min warm up Multi-wavelength Up to 10 wavelengths, up to 20 wavelengths with PC software Calculations Ratio, difference, formulae with factors Spectrum range Any range between 190 and 1100nm Scan speed 100 to 2000nmmin Scan interval 0.1, 0.2, 0.5, 1, 2 or 5nm Analysis Auto peaks and valleys, zoom, addition, subtraction, peak ratios, smoothing, wavelength table, derivatives, overlay with PC software Kinetics Up to 12 hours with time intervals of 0.1, 0.2, 0.5, 1, 2, 5, 10 or 30 seconds Analysis Slope and formula of line of best fit between any two points Quantitation points Up to 3 wavelengths Quantitation Calibration Blank with up to 10 standards or factor Concentration range 0- 99999 Calibration Blank with standards or factor DNA RNA and Protein DNARNA Ratio, concentration, A320 correction Light source Tungsten halogen and Deuterium lamps Lamp changeover 325 to 370nm selec table Outputs USB and parallel Operating system: Windows 2000, XP, Vista, Windows 7 Electrical supply 120VA, 220 110V, 50 60Hz Size (w x d x h) 600 x 450 x 200mm Weight 22kg