選擇品牌
- Neware
- Pine Research
- OKOndt Group
- Novocontrol
- Norecs
- METERTEST
- Microrad
- Metrel
- Labdex
- SDT
- micrux
- AARONIA AG
- ADASH
- Amptek
- AOiP
- AstroNova
- AWSensors
- Automatic Research
- BASI
- BRS
- BWB Technologies
- Cmc
- CTRL
- CALMET
- CHECKLINE
- Coxem
- C-Tech
- DV Power
- DANATRONICS
- ECH
- Elsys
- Enervac
- Enapter
- ELVEFLOW
- EA Technology
- EL-CELL
- ENERGY SUPPORT
- Electrothermal
- FASTEC
- GE
- GMW
- Gaskatel
- GIUSSANI
- Globecore
- GREENLIGHT
- GRZ
- HTW
- HIGH SENSE SOLUTIONSHTW
- HUBER
- Labnics
- Ida
- LIQUID
- Instytut Fotonowy
- KEHUA TECH
- JGG
- HVPD
- Jenway
- Jacomex
- IVIUM
- ndb
- OZM
- Redoxme
- Serstech
- SATIR
- VacCoat
- Zurich
- Neware
- Pine Research
- OKOndt Group
- Novocontrol
- Norecs
- METERTEST
- Microrad
- Metrel
- Labdex
- SDT
- micrux
- AARONIA AG
- ADASH
- Amptek
- AOiP
- AstroNova
- AWSensors
- Automatic Research
- BASI
- BRS
- BWB Technologies
- Cmc
- CTRL
- CALMET
- CHECKLINE
- Coxem
- C-Tech
- DV Power
- DANATRONICS
- ECH
- Elsys
- Enervac
- Enapter
- ELVEFLOW
- EA Technology
- EL-CELL
- ENERGY SUPPORT
- Electrothermal
- FASTEC
- GE
- GMW
- Gaskatel
- GIUSSANI
- Globecore
- GREENLIGHT
- GRZ
- HTW
- HIGH SENSE SOLUTIONSHTW
- HUBER
- Labnics
- Ida
- LIQUID
- Instytut Fotonowy
- KEHUA TECH
- JGG
- HVPD
- Jenway
- Jacomex
- IVIUM
- ndb
- OZM
- Redoxme
- Serstech
- SATIR
- VacCoat
- Zurich
62 Series Fluorimeter
62 Series Fluorimeter 型號:62 Series Fluorimeter- High quality optics: pulsed xenon lamp and Total Energy Transfer (TET)
- Intelligent Filter Modules ensure correct filters are fitted for selected method
- Intuitive programming allows fast program creation
- Raw fluorescence or concentration values options
- Standard curve and kinetic functions
- Heated sample holder and sipper pump accessories
- Compatible with DataWay PC software
-
Feature 62 Series Fluorimeter Wavelength selec tion Intelligent Filter Modules (IFM) Light source Pulsed Xenon lamp with press-to-read operation Expected life of lamp No replacement required in normal operation Raw fluorescence readings Yes Concentration standard curve Blank + up to 6 standards Kinetics, timed option In both raw fluorescence and concentration modes Kinetics options 1 reading every 3 to 999 seconds No. methods stored 20 No. results stored 100 per method GLP Method lock with password access. Time and date stamped results. Last calibration date and time stored. Calibration interval set. Calibration due reminder. User ID Outputs RS232 PC software Compatible with DataWay (option) Sample handling 10mm square cuvette holder (standard). Heated sample holder (option). Sipper pump (option) Power supply 90 to 230V universal mains adapter 12V DC input Size (w x d x h) 365 x 272 x 160mm Weight 6kg -
Parameter 6270 6280 6285 Wavelength range 190 to 1100nm 190 to 650nm 190 to 850nm Sensitivity1 1µg/ml <1ng/ml <1ng/ml Dynamic range1 5.2x104 5.2x106 5.2x106 Detector Photodiode PMT2 PMT2